background image

page 3

page 10

MEM

MODE

LED STROBOSCOPE

ESL-200

ADJUST

PHASE

2

2

F0

3000.0

FPM

F0

3000.0

FPM

LOW BATT

EXT

FLASH RATE
EXTERNAL TRIGGER ICON
BLACK DOT INDICATOR

APPEARS IF CURRENT FLASH RATE IS

ALREADY STORED IN MEMORY
APPEARS IN EXTERNAL TRIGGER MODE WHEN

PHASE IS SHIFTED FROM ORIGINAL POSITION 

LOW BATTERY ICON
FLASH DURATION LEVEL

F0~F9 (F0 DEFAULT)

FLASH DURATION IN POWER SAVE MODE

L0~L9 (L0 DEFAULT)

MEMORY LOCATIONS

9 LOCATIONS EACH FOR BOTH FPM AND HZ

BATTERY STATUS INDICATOR
UNITS

FPM = FLASHES PER MINUTE

HZ = FLASHES PER SECOND

DEG = ° (EXTERNAL TRIGGER MODE ONLY)

1

2

3

4
5

6

7

LCD DISPLAY

LED INDICATOR

POWER SWITCH

CLICK AND RELEASE TO TURN ON,

CLICK TO TURN OFF. 

AUTO SHUT OFF: 5 MINUTES

AC ADAPTER/CHARGER PORT

INPUT PORT

OUTPUT PORT

MEMORY KEY

SAVE VALUES 

CLEAR MEMORY

MODE KEY

CHANGE MODES

PROGRAMMING

PHASE SHIFT

PHASE SHIFT

ROTATION/POSITION

UP/DOWN ARROW KEYS  

OR 

CHANGE FLASH RATE

CHANGE FLASH DURATION LEVEL

SELECT PROGRAM OPTIONS

X2/÷2 KEYS

DOUBLE OR HALVE THE FLASH RATE

LEFT/RIGHT ARROW KEYS  

OR 

SELECT PROGRAM OPTIONS

LCD DISPLAY

1

2

3

6

4

5

7

Specifications

Range, Resolution

12.0 – 9999.9 fpm/rpm, ±0.1 fpm/rpm

10000 – 150000 fpm/rpm, ±1 fpm/rpm 

Display flashes over 100000 rpm

Brightness

4300 LUX 6,000 FPM, at 8" distance, flash duration F0

Selectable Units:

FPM or Hz

Accuracy

±0.01%, ±1 LSD

Power 

NiMH rechargeable battery

Display

12mm, 5 digit LCD  

Phase Shift

with external trigger: 0 - 359° in 1° increments

without external trigger: Image positioning only

Tripod Thread

¼ - 20 UNC  

Operating Temperature

0 – 45°C

Storage Temperature

-10 – 50°C

Weight 

.77 lb/350 g

Содержание DSL-200

Страница 1: ...INSTRUCTION MANUAL S C H M I D T c o n t r o l i n s t r u m e n t s Stroboscope DSL 200 ...

Страница 2: ... to 150 000 fpm rpm Push button operation with x2 and 2 buttons for quick adjustment Store 9 flash rates in memory for both FPM and Hz for quick retests Highly stable drift free operation Rugged aluminum housing compact size ergonomic design Tripod mountable Easy to read 5 digit 0 47 12 mm high LCD External Trigger Important Do not look directly at the emitted light Instrument is fragile handle wi...

Страница 3: ...S EACH FOR BOTH FPM AND HZ BATTERY STATUS INDICATOR UNITS FPM FLASHES PER MINUTE HZ FLASHES PER SECOND DEG EXTERNAL TRIGGER MODE ONLY 1 2 3 4 5 6 7 LCD DISPLAY LED INDICATOR POWER SWITCH CLICK AND RELEASE TO TURN ON CLICK TO TURN OFF AUTO SHUT OFF 5 MINUTES AC ADAPTER CHARGER PORT INPUT PORT OUTPUT PORT MEMORY KEY SAVE VALUES CLEAR MEMORY MODE KEY CHANGE MODES PROGRAMMING PHASE SHIFT PHASE SHIFT R...

Страница 4: ...to change the flash rate using that increment 4 Press to turn off the strobe the display remains for two more minutes The strobe shuts off automatically after 10 minutes PREPARATION Changing Units FPM is the factory default Turn off the strobe the strobe light goes off and the display stays on for two more minutes Press and hold MODE then press the power switch and SEL is displayed Press the or ar...

Страница 5: ...ct a memory location see Memory Recall above The black dot indicates the stored flash rate matches the current flash rate Use the arrow keys to change the flash rate the black dot disappears To save the new flash rate press and hold MODE then press MEM The black dot reappears and shows that the current flash rate is stored Clearing All Memory Turn off the strobe Press and hold the MODE key and the...

Страница 6: ...the or arrows to select F0 F1 F2 F9 The selected flash duration level becomes the default when the strobe is powered on Press to exit 3000 0 FPM F0 SELECT WITH UP DOWN ARROWS F0 F1 F9 SEL FPM F0 SELECT WITH UP DOWN ARROWS F0 F1 F9 POWER MANAGEMENT Auto Shut Off After your stroboscope is turned ON the instrument automatically powers off after five minutes of non use To disable auto shut off turn OF...

Страница 7: ...lash durations are brighter and less sharp 3000 0 FPM l0 SELECT WITH UP DOWN ARROWS l0 l1 l9 EXTERNAL TRIGGER INPUT Insert a 3 5mm phone plug into the input port at the base of the strobe When the strobe receives an input signal the External Trigger icon EXT appears at the top left of the display The strobe s flash rate corresponds to the frequency of the input signal The display indicates this ra...

Страница 8: ...00 ADJUST PHASE 2 2 3000 0 3000 0 3000 0 INDUCTIVE PROXIMITY SENSOR 1 PULSE PER REVOLUTION AC ADAPTER SLAVE SLAVE MORE UNITS HANDHELD OR TRIPOD MOUNT EXTERNAL OUTPUT TO SLAVE INPUT External Trigger Application Optional External Trigger Kit ET 1 Cascade Application To synchronize two or more stroboscopes connect one output port to the other strobe s input port slave unit DSL 200 DSL 200 ...

Страница 9: ...CHARGING Digital Phase Shift Only w external trigger The input signal s cycle is 360 Press the phase and keys to view the delayed angle of the input cycle The range of this adjustment phase shift is 0 to 359 The angle appears on the display when the and keys are pressed and three seconds after they are released the display returns to flashes per minute while maintaining the phase shift setting The...

Страница 10: ... LUX 6 000 FPM at 8 distance flash duration F0 Selectable Units FPM or Hz Accuracy 0 01 1 LSD Power NiMH rechargeable battery Display 12mm 5 digit LCD Phase Shift with external trigger 0 359 in 1 increments without external trigger Image positioning only Tripod Thread 20 UNC Operating Temperature 0 45 C Storage Temperature 10 50 C Weight 77 lb 350 g ...

Страница 11: ...page 11 Dimensions MEM MODE LED STROBOSCOPE ESL 200 ADJUST PHASE 2 2 190 7 48 30 1 18 1 4 20 UNC TRIPOD MOUNT 74 2 91 33 1 29 AC ADAPTER PORT INPUT PORT OUTPUT PORT ...

Страница 12: ...of the products and the purchaser s exclusive remedy against Hoto Instruments under any warranty shall be limited to the repair or replacement at Hoto Instruments option of product components not conforming to the warranty PURCHASER S DAMAGES AND LIMITATIONS In no event shall Hoto Instruments be liable to pur chaser its assigns or agents for economic loss incidental or consequential damages in con...

Отзывы: