Name of the component:

SLC440COM Series

SLG440COM Series

Type:

See ordering code

Description of the component:

Safety light curtain / safety light grid

Relevant Directives:

Machinery Directive

RED-Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/53/EU

2014/30/EU

2011/65/EU

Applied standards:

EN 61496-1:2013,

EN 61496-2:2013,

EN ISO 13849-1:2015,

EN 62061:2005 + Cor.:2010 + A1:2013 + A2:2015

Notified body for the prototype test:

TÜV NORD CERT GmbH

Langemarckstr 20, 45141 Essen

ID n°: 0044

EC-prototype test certificate:

44 205 13144609

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

Place and date of issue:

Mühldorf, May 11, 2020

Authorised signature

Klaus Schuster

Managing Director

Authorised signature

Christian Spranger

Managing Director

EU Declaration of conformity

Original

Safety Control GmbH

Am Industriepark 2a

84453 Mühldorf / Inn

Germany

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives 

The currently valid declaration of conformity can be  

downloaded from the internet at productsschmersalcom

10.  EU Declaration of conformity

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30, 42279 Wuppertal

Germany

Phone:  +49 202 6474-0

Telefax:  +49 202 6474-100

E-Mail: [email protected]

Internet: www.schmersal.com

Содержание SLC440COM Series

Страница 1: ...ion 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liabil...

Страница 2: ...ccept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual The manufacturer shall accept no liability for damages re...

Страница 3: ...oad inductance 4 0 2H Function protective mode automatic restart interlock setting mode Connection Emitter connector M12 4 pole Receiver connector M12 5 pole Ambient temperature 10 C 50 C Storage temp...

Страница 4: ...ction zone interrupted OSSD signal low Green ON state protection zone uninterrupted OSSD signal high 2 9 2 Restart Interlock operation In the operating mode restart interlock the safety switching outp...

Страница 5: ...ta or cyan For the parameter setting follow the instructions as described in the section Parameter setting with adapter cable KA 0896 4 Mounting 4 1 General conditions The following guidelines are pro...

Страница 6: ...llow operating mode restart interlock 3 Adjust the emitter and receiver so that they are in the middle of the angular range for a green or yellow indication Fix the position with the two screws for ea...

Страница 7: ...is exposed to serious injuries To calculate the minimum distances of the safety guards with regards to the hazardous point the EN ISO 13855 and EN ISO 13857 must be observed If an overlap of the prote...

Страница 8: ...e 1 Locate the height of the upper edge of the hazardous area a left table column 2 Locate the height of the protection area b upper table row 3 CRO is to be taken from the crossing point of both axes...

Страница 9: ...h neighbouring safety light barriers grids of the same type AOPD is excluded If two or more applications are arranged so that mutual interference is possible this should be eliminated with a partition...

Страница 10: ...C440COM ER 0970 xx Ls 1024 13 1011 mm 4 8 Dimensions 4 8 1 Dimensions emitter and receiver SLC440COM All measurements in mm 75 A B C 22 2 24 7 7 33 27 8 Type A Protected height 1 B Mounting dimension...

Страница 11: ...on description Length 103010816 A K5P M12 S G 5M BK 2 X A 4 69 Female connector M12 5 pole 5 m 103010818 A K5P M12 S G 10M BK 2 X A 4 69 Female connector M12 5 pole 10 m 103010820 A K5P M12 S G 15M BK...

Страница 12: ...ed BK 24 VDC BN 0 VDC BU Release restart GY 24 VDC BN OSSD 2 BK OSSD 1 WH 0 VDC BU Not connected WH Protective mode Automatic active Delivery state Pushbutton S1 not connected Restart Interlock manual...

Страница 13: ...of the emitter is correctly connected to the emitter and the connecting cable of the receiver is correctly connected to the receiver 4 The double insulation between the light curtain output and an ex...

Страница 14: ...Green static Status of OSSD safety switch outputs is ON protection field is clear OSSD OFF Red static Status of OSSD safety switch outputs is OFF the protection field is interrupted Restart interlock...

Страница 15: ...003 This device complies with Industry Canada s license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accep...

Страница 16: ...205 13144609 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue M hldorf May 11 2020 Authorised signature Klaus S...

Отзывы: