Operate the machine and check whether the hazardous movement
stops under the hereafter mentioned circumstances.
1 Hazardous machine parts do not move when the protection field is
interrupted
2 The hazardous machine movement is immediately stopped, when
the protection field is interrupted with the test rod directly at the
emitter, directly at the receiver and in the middle between the emitter
and the receiver
3 No hazardous machine movement when the test rod is within the
protection field
4 The hazardous machine movement comes to standstill, when the
voltage supply of the AOPD is switched off
6.4 Half-yearly inspection
The following items must be checked every six months or when a
machine setting is changed
1 Machine stops or does not inhibit any safety function
2 No machine modification or connection change, which affects the
safety system, has taken place
3 The outputs of the AOPD are correctly connected to the machine
4 The total response time of the machine does not exceed the
response time calculated during the first commissioning
5 The cables, the connectors, the caps and the mounting angles are in
perfect condition
6.5 Cleaning
If the optics cover of the sensors is extremely soiled, the OSSD outputs
may be disabled Clean with a clean, soft cloth with low pressure
The use of agressive, abrasive or scratching cleaning agents, which
could attack the surface, is prohibited
7. Diagnostic
7.1 Status information
Signalisation of the status occurs at the receiver end cap
Status display - receiver
Operating
condition
Display
Description
OSSD ON
Green, static Status of OSSD safety switch
outputs is ON, protection field is
clear
OSSD OFF
Red,
static
Status of OSSD safety switch
outputs is OFF,
the protection field is interrupted
Restart interlock
(manual reset)
Yellow, static Restart interlock is active,
protection zone is clear,
enable signal expected
Error
Red, pulses Fault status, see section on fault
indication
Parameter
setting
Cyan, pulses
Magenta,
pulses
See section Parameter setting
Setting mode,
indication of
signal strength
Blue, pulses See section Setting mode
Display of
signal strength
Green,
one pulse for
every 5
seconds
Dirt indicator, signal strength
insufficient
Status display - emitter
Signalisation of the general status occurs at the emitter end cap
Emitter end
plug
Status
Description
Transmitting Orange
Standard operation, emitter active
Orange flashing Fault status
7.2 Fault diagnostic
The status indication lights up permanently and indicates the fault
number every second with short pulses
Status indi-
cator
Fault feature
1 impulse
Wiring fault
2 impulses
Voltage fault, check the supply voltage
3 impulses
Error output OSSD1 or OSSD2
4 impulses
Internal error diagnostic
6 impulses
Incorrect configuration data
7 impulses
Other internal fault
8. Disassembly and disposal
8.1 Disassembly
The safety switchgear must be disassembled in a de-energised
condition only
8.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations
9. Appendix
9.1 Contact
Consultancy / Sales:
K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
D-42279 Wuppertal
Tel.: +49 (0)2 02 - 64 74 - 0
Fax: +49 (0)2 02 - 64 74 - 100
You will also find detailed information regarding our product variety on
our website: wwwschmersalcom
Repair/shipping:
Safety Control GmbH
Am Industriepark 2a
D-84453 Mühldorf/ Inn
Tel.: +49 (0) 86 31 - 1 87 96 - 0
Fax: +49 (0) 86 31 - 1 87 96 - 1