1. About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional 

information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC  . . . . . . . . . . . . . .2

2.4  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.6 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.3  Actuating positions of the safety sensor with regard to the actuator 4

3.4  Switch distance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.5  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

4.2  Series-wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5  Diagnostic functions

5.1  Operating principle of the diagnostic LEDs  . . . . . . . . . . . . . . . . . . .6

5.2  Operating principle of the electronic diagnostic output  . . . . . . . . . .6

5.3  Safety-sensors with serial diagnostic function . . . . . . . . . . . . . . . . .7

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

8  Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

8.2  Wiring of the safety sensor with cable or integrated connector . . . 11

9  EU Declaration of conformity

x.000 / 01.2020 / v

.A.   -   101

191603-EN / F / 2020-01-10 / 

AE-Nr

. 1

1847

EN

Operating instructions. . . . . . . . . . . .pages 1 to 12

Original

Содержание CSS 34F0

Страница 1: ...formation regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructio...

Страница 2: ...ditionally executes functions of a safety monitoring module At both safety outputs two auxiliary contactors1 or relays1 can be connected whose safety related function is checked by the sensor by means...

Страница 3: ...3 1 General mounting instructions Please observe the relevant requirements of the standards ISO 12100 ISO 14119 and ISO 14120 The component can be mounted in any position The active surface of the sa...

Страница 4: ...ST 34 S 1 CSS 34 S CST 34 V 1 CSS 34 V CST 34 S 3 CSS 34 S CSS 34 V CST 34 S 3 CST 34 S 2 CSS 34 S CSS 34 V CST 34 S 2 CST 180 1 2 CSS 34 S CSS 34 V CST 180 1 2 3 4 Switch distance Actuators and switc...

Страница 5: ...es of max 500 s must be tolerated by the switching device An extension with short circuit recognition for the evaluation is not required Note on the total length of a safety sensor chain refer to para...

Страница 6: ...The diagnostic output can also be used to detect clearance variations between the sensor and the actuator in the same way as the yellow LED An active fault causes the diagnostic output to be disabled...

Страница 7: ...fault Error warning A fault has occurred which causes the safety outputs to be disabled after 30 minutes The safety outputs initially remain enabled This enables the shutdown of the process in a cont...

Страница 8: ...1 3 Only version F1 reset button actuation No change compared to 2 The yellow LED is on both connected relays are enabled 1 If no button is used the feedback circuit must be opened by loosening the c...

Страница 9: ...enabled by the feedback circuit which is built by the NC contacts of K1 K2 As no further button is used the auxiliary contactors1 or relays1 are immediately enabled when the safety guard is closed The...

Страница 10: ...eedback circuit reset button Load Field Control cabinet n participants Wiring example 3 Wiring example for a series wiring of the CSS 34 and CSS 34F1 safety sensors with serial diagnostic outputs The...

Страница 11: ...y 8 2 Wiring of the safety sensor with cable or integrated connector Function safety switchgear Pin configuration of the connector 5 8 4 3 2 1 7 6 Colour codes of the Schmersal connectors Poss colour...

Страница 12: ...certificate 01 205 5194 02 19 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal 13 November 2019 Autho...

Отзывы: