11
CSS 34F0
CSS 34F1
Operating instructions
Safety sensor
EN
Wiring example 4:
Wiring example of the CSS 34F0 safety sensor with conventional diagnostic output wired with auxiliary relays for controlling auxiliary
contactors
1)
with actuating currents > 250 mA
Additional auxiliary relays are used, when the power of the safety outputs of the safety sensor is insufficient to directly control the auxiliary contactors
1)
. The NO contacts of the load-switching auxiliary contactors
1)
are monitored.
Optional executions of the feedback circuit with one button, refer to previous wiring examples.
24 V
0 V
WH
VT
GY
RD
BK
0 V
BN
BU
CS
T 3
4-
S-
1
CS
S 1
4-
34
F0
-S
-D
-M
-L
L1
L1 L2 L3
K1
K2
positive-guided auxiliary
contactors
Load
Load on/off
Field
Control
cabinet
Relay
8.2 Wiring of the safety sensor with cable or integrated connector
Function safety switchgear
Pin configuration
of the connector
5
8
4
3
2
1
7
6
Colour codes of the Schmersal
connectors
Poss. colour codes of other
customary connectors
or the integrated
cable
with conventional
diagnostic output
with serial
diagnostic function
IP67 / IP69
to DIN 47100
IP69K
(PVC)
to
IEC 60947-5-2: 2007
A1
U
e
1
WH
BN
BN
X1
Safety input 1
2
BN
WH
WH
A2
GND
3
GN
BU
BU
Y1
Safety output 1
4
YE
BK
BK
OUT
Diagnostic output
SD output
5
GY
GY
GY
X2
Safety input 2
6
PK
VT
PK
Y2
Safety output 2
7
BU
RD
VT
IN
without function
SD input
8
RD
PK
OR
Connecting cables with coupling (female)
IP67 / IP69, M12, 8-pole - 8 x 0.23 mm²
to DIN 47100
Connecting cables with coupling (female)
IP69K, M12, 8-pole - 8 x 0.21 mm²
Cable length
Part number
Cable length
Part number
2.5 m
5.0 m
10.0 m
103011415
103007358
103007359
5.0 m
5.0 m, angled
10.0 m
15.0 m
101210560
101210561
103001389
103014823