2
The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety
level. If multiple safety sensors are involved in the same safety function, the PFH values of the individual components must
be added.
2
The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant
standards.
2.4 Warning about misuse
2
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant
components cannot be excluded. There are no residual risks, provided that the safety instructions as well as the
instructions regarding mounting, commissioning, operation and maintenance are observed.
2.5 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply
with the operating instructions manual. The manufacturer shall accept no liability for damages resulting from the
use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the
device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive
work, arbitrary repairs, conversions and/or modifications to the device.
2.6 Technical Data
認証
証明書
TÜV
cULus
ECOLAB
EAC
FCC
IC
一般データ
規格
EN ISO 13849-1
EN ISO 14119
EN IEC 60947-5-3
EN IEC 61508
一般情報
ユニバーサルコード化
Coding level according to EN ISO 14119
Low
アクティブ原理
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m