Table 2: Error messages / flash codes red diagnostic LED

Flash pulses
(red)

Designation

Autonomous switch-off
after

Error cause

1 flash pulse

Error (warning) at output Y1

30 min

Fault in output test or voltage at output Y1, although the
output is disabled.

2 flash pulses

Error (warning) at output Y2

30 min

Fault in output test or voltage at output Y2, although the
output is disabled.

3 flash pulses

Error (warning) cross-wire
short

30 min

Cross-wire short between the output cables or fault at both
outputs

4 flash pulses

Error (warning) temperature
too high

30 min

The temperature measurement reveals an internal
temperature that is too high

5 flash pulses

Actuator fault

0 min

Incorrect or defective actuator, bracket broken

6 flash pulses

Fault rotary handle

0 min

Rotary handle not in authorised intermediate position

Continuous red
signal

Internal error

0 min

Device defective

6.5 Solenoid interlock with serial diagnostic function SD

Solenoid interlocks with serial diagnostic cable have a serial input and output cable instead of the conventional
diagnostic output. If solenoid interlocks are wired in series, the diagnostic data are transmitted through the series-
wiring of the inputs and outputs.

Max. 31 solenoid interlocks can be wired in series. For the evaluation of the serial diagnostics line either the PROFIBUS-
Gateway SD-I-DP-V0-2 or the Universal-Gateway SD-I-U-... are used. This serial diagnostic interface is integrated as
slave in an existing field bus system. In this way, the diagnostic signals can be evaluated by means of a PLC.

The necessary software for the integration of the SD-Gateway is available for download at products.schmersal.com.

The response data and the diagnostic data are automatically and permanently written in an input byte of the PLC for
each solenoid interlock in the series-wired chain. The request data for each solenoid interlock is transmitted to the
component through an output byte of the PLC. In case of a communication error between the SD-gateway and the
solenoid interlock, the switching condition of the solenoid interlock is maintained.

Error

Errors which no longer guarantee the function of the safety switchgear (internal errors) cause the safety outputs to be
disabled within the duration of risk. The fault is reset, when the cause is eliminated and bit 7 of the request byte
changes from 1 to 0 or the safety guard is opened. Faults at the safety outputs are only deleted upon the next release,
as the fault rectification cannot be detected sooner.

Fault warning

A fault that does not immediately endanger the safety function of the safety switchgear (e.g. too high ambient
temperature, safety output at external potential, cross-circuit) leads to delayed shutdown (see Table 2). This signal
combination, diagnostic output disabled and safety channels still enabled, can be used to stop the production process
in a controlled manner. An error warning is deleted when the cause of error is eliminated. If the fault warning remains
on for 30 minutes, the safety outputs are also switched off (red LED flashes, see Table 2).

Содержание AZM300Z-I2-ST-1P2P-N-DU

Страница 1: ...e 3 3 Emergency exit T T8 or emergency release N 3 4 Mounting with mounting plate 3 5 Dimensions 3 6 Actuator and accessories 4 Electrical connection 4 1 General information for electrical connection...

Страница 2: ...ations regarding occupational safety and accident prevention prior to installation and putting the component into operation The machine builder must carefully select the harmonised standards to be com...

Страница 3: ...iption 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety...

Страница 4: ...is to be used marked with the symbol in the ordering code The actuator monitoring variant B is a safety switch with an interlock function for process protection The safety function consists of safely...

Страница 5: ...maintenance are observed 2 5 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with the operating instructions ma...

Страница 6: ...Features Power to unlock Yes Solenoid interlock monitored Yes Latching Yes Emergency release Yes Short circuit detection Yes Cross circuit detection Yes Series wiring Yes Safety functions Yes Integral...

Страница 7: ...tching force adjustable position 2 50 N Type of the fixing screws 2x M6 Tightening torque of the fixing screws minimum 6 Nm Tightening torque of the fixing screws maximum 7 Nm Mechanical data Switchin...

Страница 8: ...Protection class III Permissible installation altitude above sea level maximum 2 000 m Ambient conditions Insulation values Rated insulation voltage U i 32 VDC Rated impulse withstand voltage U imp 0...

Страница 9: ...Switching thresholds 3 V 5 V Low 15 V 30 V High Current consumption at 24V 5 mA Test pulse duration maximum 1 ms Test pulse interval minimum 100 ms Classification ZVEI CB24I Sink C1 Classification ZVE...

Страница 10: ...X1 Safety input 1 PIN 3 A2 GND PIN 4 Y1 Safety output 1 PIN 5 OUT Diagnostic output PIN 6 X2 Safety input 2 PIN 7 Y2 Safety output 2 PIN 8 IN Solenoid control Note about the safety classification 2 Th...

Страница 11: ...must be supplied with at least 24 V DC and 0 8 A via a listed CYJV cable connector assembly FCC IC Note This device complies with Part 15 of the FCC Rules and contains licence exempt transmitter rece...

Страница 12: ...d be reduced Mounting of the solenoid interlock and the actuator Refer to the mounting instructions manual for the corresponding actuator 2 The actuator must be permanently fitted to the safety guards...

Страница 13: ...orrect False To avoid any interference inherent to this kind of system and any reduction of the switching distances please observe the following guidelines The presence of metal chips in the vicinity...

Страница 14: ...mm 3 2 Manual release For the machine set up the solenoid interlock can be unlocked in a de energised condition The solenoid interlock is unlocked by turning the manual release in the position qThe no...

Страница 15: ...fter completing commissioning 3 3 Emergency exit T T8 or emergency release N With variants that have both emergency exit and emergency release the red lever is loosely supplied Before first use mount...

Страница 16: ...at it should only be used in an emergency The label can be used that was included in the delivery To activate the emergency release turn the red lever in the direction of the arrow to the end stop The...

Страница 17: ...3 5 Dimensions All measurements in mm AZM300 T T8 and N Device with emergency exit or emergency release Emergency exit T Emergency release N...

Страница 18: ...Emergency exit T8 3 6 Actuator and accessories Actuator AZ AZM300 B1 not included in delivery Mounting plate MP AZ AZM300 1 available as accessory...

Страница 19: ...MS AZ AZM300 B1 1 available as accessory Aluminium protective plate as a cover for use on glass and plastic doors on machines with high design requirements Lockout tag SZ 200 1 available as accessory...

Страница 20: ...n cable release 4 Electrical connection 4 1 General information for electrical connection 2 The electrical connection may only be carried out by authorised personnel in a de energised condition The vo...

Страница 21: ...op on the cables and the current carrying capacity of the individual components F Accessories for the series wiring For convenient wiring and series wiring of SD components the SD junction boxes PFB S...

Страница 22: ...serial diagnostics connections are wired in series and connected to a SD Gateway for evaluation purposes The safety outputs of the first safety component are wired to the safety monitoring module The...

Страница 23: ...SD output 5 GY GY GY X2 Safety input 2 6 PK VT PK Y2 Safety output 2 7 BU RD VT IN Solenoid control SD input 8 RD PK OR Connecting cables with coupling female IP67 IP69 M12 8 pole 8 x 0 25 mm to DIN 4...

Страница 24: ...an unlimited number of times When a new actuator is taught the code which was applicable until that moment becomes invalid Subsequent to that an enabling inhibit will be active for ten minutes thus p...

Страница 25: ...it upstream is open Flashes 1 Hz Off On 6 4 Solenoid interlock with conventional diagnostic output The short circuit proof diagnostic output OUT can be used for central visualisation or control tasks...

Страница 26: ...be locked or fault Legend Safety guard open Safety guard closed Locking time Safety guard not locked or fault Safety guard locked Lock Unlock Evaluation of diagnostic output Power to unlock IN 0 Lock...

Страница 27: ...king impossible 0 V 24 V On Off Flashes 0 V 24 V 0 V Safety guard closed and locked 0 V 24 V On Off On 24 V 24 V 24 V Error warning1 0 V 24 V On Flashes 2 On 24 V1 24 V1 0 V Error 0 V 24 V 24 V 0 V On...

Страница 28: ...d as slave in an existing field bus system In this way the diagnostic signals can be evaluated by means of a PLC The necessary software for the integration of the SD Gateway is available for download...

Страница 29: ...be unlocked if e g the door pulls the turret out of its rest position beyond the set latching force This can occur if doors are heavily distorted or when pulling the door The solenoid interlock can o...

Страница 30: ...ns of replacement actuators 2 Damaged or defective components must be replaced 8 Disassembly and disposal 8 1 Disassembly The safety switchgear must be disassembled in a de energised condition only 8...

Отзывы: