Power to lock: IN = 1 = Lock
Safety guard can be locked
Safety guard locked
Table 1: Diagnostic information of the safety switchgear
System condition
Magnet control IN
LED
Safety outputs Y1,
Y2
Diagnostic
output OUT
Power to
unlock
Power to
lock
green
red
yellow
AZM300Z
AZM300B
Safety guard open
24 V (0 V)
0 V (24 V)
On
Off
Off
0 V
0 V
0 V
Safety guard closed,
not
locked
24 V
0 V
On
Off
Flashes
0 V
24 V
24 V
Safety guard closed,
locking
impossible
0 V
24 V
On
Off
Flashes
0 V
24 V
0 V
Safety guard closed and locked
0 V
24 V
On
Off
On
24 V
24 V
24 V
Error warning
1)
0 V
24 V
On
Flashes
2)
On
24 V
1)
24 V
1)
0 V
Error
0 V (24 V)
24 V (0 V)
On
Flashes
2)
Off
0 V
0 V
0 V
No input signal at X1 and/or X2
0 V (24 V)
24 V (0 V)
Flashes
Off
Off
0 V
0 V
0 V
No input signal at X1 and/or X2
0 V (24 V)
24 V (0 V)
Flashes
Off
On/Flashes
0 V
0 V
24 V
Additionally for variant I1/I2:
Teach-in procedure actuator
started
Off
Off
Flashes
0 V
0 V
0 V
Only I2: teach-in procedure
actuator (release block)
Flashes
Off
On
0 V
0 V
0 V
1)
after 30 min: disabling due to fault
2)
refer to flash code