Schmalz X-Pump
Brief operating instructions
4-26
S
CHMALZ
Displaying the internal counters
Press and hold
<MENU>
and
<UP>
for at least three seconds.
Use the
<UP>
or
<DOWN>
key to select the desired counter.
Press
<ENTER>
to confirm the selection.
The three low-order digits of the total counter value are displayed and the
rightmost LED (out2-h/c) lights.
The
<UP>
and
<DOWN>
keys can be used to display the other digits of the
counter value. The LEDs indicate which group of digits is being displayed, as
follows:
LED out2-h/c:
displaying 10
0
LED out2-H/C:
displaying 10
3
LED out1-h/c:
displaying 10
6
LED out1-H/C:
displaying 10
9
The total counter value consists of four groups of three digits each.
Example:
The current counter value is 48,618,593.
Resetting the internal cycle counters [rct]
Press and hold
<MENU>
and
<UP>
for at least three seconds.
Use the
<UP>
or
<DOWN>
key to select the menu item
[rct]
.
Press and hold the
<ENTER>
key for at least three seconds.
The display then blinks to indicate that all three counters have been reset to
zero.
If the
<ENTER>
is not held down for at least three seconds, the counters will
not be reset.
Exit from the counter function by pressing
<MENU>
.