Schmalz X-Pump
Brief operating instructions
4-22
S
CHMALZ
H1
Deactivation value for air-saving
function
H2
Activation value of output of part pre-
sent
h1
Hysteresis of air-saving function
h2
Hysteresis of output of part present
H1-h1
Activation value for air-saving
function
H2-h2
Deactivation value of output of part
present
Setting the threshold values [H-1], [h-1], [H-2], [h-2]
The order of the parameters in the menu is shown in the diagram above.
Press the
<MENU>
key.
If the menu is locked, enter the appropriate PIN.
Use the
<UP>
or
<DOWN>
key to select the desired parameter.
Press
<ENTER>
to confirm the selection.
Use the
<UP>
or
<DOWN>
key to change the value.
Press the
<ENTER>
key to save the new setting.
The next parameter is now displayed automatically.
The four yellow LEDs below the display show which value is currently being set.
If the
<UP>
or
<DOWN>
key is pressed and held, the value to be changed is
incremented rapidly.
If you exit from the menu by pressing the
<MENU>
key after changing a value,
the new value is not saved.