Problem
Cause
Solution
Pump does not start
Elect. connection reversed, faulty
Check connection; correct if necessary
Motor protection switch triggered
Check
Voltage only on two phases
Check connection/fuse
Power consumption increased
Check motor for fault; is it overheated?
(allow to cool),
clean water separator
Power supply interrupted
Check the power supply line
Vacuum pump not working properly
Check pump/contact customer service
Vacuum pump is
running, but is not
picking up
Rotational direction reversed
Check connection; correct if necessary
Manual slide valve on control handle is
in “Release” position
Move the manual slide valve on control
handle to the “Clamp” position
Manual slide valve faulty
Repair/replace
Suction chamber is switched on and the
workpiece is not completely covering it
or the suction chamber is not being
completely used
Switch off the corresponding suction
chamber using the manual slide valve
on the suction plate when the remaining
load-bearing capacity is greater or the
same as the workpiece weight.
A suction chamber which is not covered
by the workpiece is open
Switch off the corresponding suction
chamber using the manual slide valve.
Filter is dirty
Clean or replace cartridge
Leaking hose/screw unions
Replace/seal components
Vacuum generator
functioning, but
workpiece is not
vacuum-gripped
Sealing lip on suction plate is
damaged
Replace suction plate
Gauge is faulty
Replace the gauge
Leaking hose/screw unions
Replace components
Workpiece has cracks,
gaps or is porous
The workpiece cannot be handled with
this lifting device
Valve faulty
Repair/replace
Warning device is
triggered
Workpiece has cracks, gaps or is
porous
The workpiece cannot be handled with
this lifting device
Sealing lip is damaged
Replace sealing lip
Faulty hose/leaking screw unions
Replace components
Vacuum switch misaligned/faulty
Contact customer service
Device does not swivel
Power supply interrupted
Check power supply line
Motor / cylinder faulty
Repair or replace the motor / cylinder
Motor and gear units are becoming
overheated
Reduce the duty cycle (cool-off phase
necessary)