TECHNICAL DATA
16 | EN
3 Technical data
3.1 General data
Operating medium
Air or neutral gas, 5 µm filtered, with or without oil, class 3-3-
3 compressed air quality acc. to ISO 8573-1
Operating pressure (Flow pressure)
2 to 6 bar (optimally 4 to 4.5 bar)
Degree of protection
IP 65
Working temperature
0 to 50 °C
Storage temperature
-10 to 60 °C
Permitted humidity
10 to 90% RH (free from condensation)
Vacuum sensor precision
3% FS
3.2 Electrical data
Power supply for sensor
24 V -20 +10% VDC (PELV)
1)
Power supply for actuator
24 V -20 +10% VDC (PELV)
1)
Sensor power consumption
2)
(at 24 V) SCTMi with 4 NC ejectors
66 mA
SCTMi with 8 NC ejectors
118 mA
SCTMi with 16 NC ejectors
219 mA
SCTMi with 4 NO ejectors
70 mA
SCTMi with 8 NO ejectors
128 mA
SCTMi with 16 NO ejectors
244 mA
Actuator power consumption
2)
(at
24 V)
SCTMi with 4 NC ejectors
83 mA
SCTMi with 8 NC ejectors
157 mA
SCTMi with 16 NC ejectors
293 mA
SCTMi with 4 NO ejectors
158 mA
SCTMi with 8 NO ejectors
298 mA
SCTMi with 16 NO ejectors
586 mA
Polarity reversal protection
Yes, all M12 connector connections
NFC
NFC Forum Tag type 4
IO-Link
IO-Link 1.1
Baud rate COM2 (38.4 Kbits/s)
1)
The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low voltage).
2)
Typical power consumption
3.2.1 IO link process data
Number of connected ejectors
Maximum cycle time
Input process
data
Output process data
2 to 4
4.0 ms
5 bytes
3 bytes
5 to 8
4.8 ms
6 bytes
4 bytes
9 to 12
5.4 ms
7 bytes
5 bytes
13 to 16
6.0 ms
8 bytes
6 bytes