Operating / Assembly manual
28
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
Pump type WK/ SMK
Version: 27220 - E
9.3.2.
Preparations for Disassembly
Before starting disassembly, the pump must be secured so that it cannot be turned on (isolated).
Caution! Danger of death!
Place a warning notice on the switch cabinet.
If the system is in operation, inform the shift manager.
9.3.3.
Disassembly / Removal of the Pump
The pump must have reached ambient temperature.
Disconnect the power supply.
Close the fittings (suction and pressure-end).
Empty the pump through the drain screws (11/11.5).
Unclamp the motor.
Disassemble any additional connections that are present.
Loosen the pressure and suction connections.
Loosen the pump from the base plate.
Lift the pump completely.
9.4.
Die sassembly / Dismantling the Pump
Before beginning:
Do not begin working until you have checked to ensure:
that all necessary spare parts are present and they match the pump or the version of the pump
you have, or that damaged parts which may still be discovered can be obtained in short order.
that all tools and auxiliary equipment required for work are available.
Note:
Use only original spare parts for repairs!
Observing these instructions is a precondition for problem-free operation of the pump and for honouring
any warranty claims that may be submitted.