OPERATOR‘S MANUAL
8
NT2 rondo
Version: 27211 -
F
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4
Installation Site Specifications / Installation
4.1
Planning the pump pit
When planning a pump pit take into account:
1. Clear dimensions min. 600 x 600 x 600
2. Return connection min. 300 mm under the pool water level.
3. Leakage water discharge pipe-end min. DN 40
4. Opening for cooling air min. 2x DN 125
5. Be sure to cover the pump pit if it is installed in the open air.
6. The position of the non-return air valve (L) must always be over the
pool water level
.
7. In case of leakage from the pump, a suitable water drainage must be provided!
Warning! Mortal danger!
If the motor is to be installed with a metal supporting foot, then it must be fa-
stened insulated against the floor to avoid the transfer of spurious voltages to
the device and swimming pool water.
Warning! Risk of damage!
As the pumps are not self-priming, the installation must be under water level.
Make sure you take this into account during the installation planning phase.
fig. 7: Cross-sectional view of the pump
pit
fig. 8: Top view of the pump pit
BWSP
Pool water level (PWL)
L
Non-return air valve
Warning! Mortal danger!
The mains power supply cable must be equipped with an all-pole separator
with a contact opening of 3 mm.
min DN 40
min 600
300
BWSP
L
2 x DN 125
min 600
8304
8305