background image

Schmalenberger GmbH + Co. KG 

D-72072 Tübingen / Germany

Control box Control NT
Version: 27248 - C

15

Subject to technical changes

4.6.3

Connection diagram 3~ mains 230V AC

Attention!
The operating voltage between L1 and N is 230V!

Higher voltages can destroy the device.
Smaller voltages can lead to malfunctions.

Sensor button
lights up

Mains input
3~ 230V / 50Hz

     

For 3~ mains 230V AC

Содержание FLUVO Control NT

Страница 1: ...27248 C Translation of the original GB Operator s Manual Control Box Control NT ...

Страница 2: ... Pump Connection Terminal 9 4 2 Connection Terminals for Control and Feedback Contacts 9 4 2 1 Feedback contact 10 4 2 2 Control contacts 10 4 2 3 Adjustable functions 10 4 3 Terminal compartment disconnection 11 4 4 Configuration using DIP switches 12 4 5 Installation Instructions 12 4 6 Connection diagrams 13 4 6 1 Connection diagram 1 mains 230V AC 13 4 6 2 Connection diagram 3 mains 400V AC 14...

Страница 3: ...ns In case of damage caused by failure to observe the information provided in these operating instructions all claims under warranty shall be void The manufacturer cannot accept any liability for resulting consequential damages The device must only be used when it is in flawless technical condition If serious operating problems occur disconnect the system from the electrical power source Eliminate...

Страница 4: ...1 Functional Variants The following functions can be selected when the device is ordered The functions are available individually or they can be combined For enabled functions please refer to the nameplate For details see section 6 2 2 Operating Display Two LEDs on the front of the control box indicate the current device status The green ope rating LED flashes four times per second immediately aft...

Страница 5: ...witch 5 see section 4 4 The pump can be turned on with the actuators The pump can optionally be switched off after the runtime elapses or after pressure is applied to the actuator again After the pump is switched off a disable time of 2 seconds is active The pump cannot be activated again until after the disable time elapses 2 5 Calibrating the Pneumatic Button Semi automatic calibration of the co...

Страница 6: ...and vice versa For programming instructions please refer to the nameplate and see section 6 When the setting is 1 phase the other two phases are checked for an impermissible cur rent If the measured current of phases V and W exceeds the set minimum current for the set minimum duration an overcurrent error is triggered for phases V and W When the setting is 3 phases all three phases are checked for...

Страница 7: ...us of the digital outputs DOUT1 to DOUT3 is displayed via the green LEDs in the converter box The output is then active when the green LED lights up Configuration The switching device and the converter box are connected via the BUS connections with a two wire cable The polarity is arbitrary In this case no other bus participants can be connected apart from the converter box See connection diagram ...

Страница 8: ...ntrol NT Version 27248 C 8 Subject to technical changes 3 Wall Installation with Dimensions Nameplate 2x cable screw connection Supply line Mains Pump cable ø7 13mm 5x cable screw connection Feedback and Control line cable ø3 5 7mm Plug nippel ø3 6mm Hose connection ...

Страница 9: ...mp Connection Terminal 4 2 Connection Terminals for Control and Feedback Contacts L1 L2 L3 N PE 3 Mains power input U V W N PE 3 Pump output L1 N PE 1 Mains power input U N PE 1 Pump output Pump output Mains power input Terminal compartment disconnection 6 5 4 3 2 1 Pump ON Malfunction Enable BUS A B 24V GND 24V Start Stop Imax 30mA Floating switching contact ...

Страница 10: ...unction service Floating N O contact Relay contact 3 Enable Input for a floating latching switching contact for example Shutter control The switching device is active when the con tact is closed In state as supplied the contact is closed with a wire bridge 4 BUS A BUS B Interface für Betrieb via Bus Connection is protected against polarity reversal For address setting see section 4 4 5 24V Connect...

Страница 11: ...e terminal chamber disconnect is inserted and can be removed for easier wiring as follows Terminal compartment disconnection Installation is in the opposite order Safety instruction A terminal chamber disconnect is provided for the connection area of the piezo button It is designed to prevent lose connecting lines from setting the piezo button under mains voltage ...

Страница 12: ...s whether input 6 Button mode will be used for a button or for a latching switch 4 5 Installation Instructions Provide a 0 03 A FI circuit breaker in the mains power supply line For the fuse see the identification on the cover of the terminal box The device bus address is set with the switches items 1 4 Hexadecimal adress item 1 item 2 item 3 0x50 OFF OFF OFF 0x51 ON OFF OFF 0x52 OFF ON OFF 0x53 O...

Страница 13: ...bject to technical changes 4 6 Connection diagrams 4 6 1 Connection diagram 1 mains 230V AC Attention The operating voltage between L1 and N is 230V Higher voltages can destroy the device Smaller voltages can lead to malfunctions Mains input 1 230V 50Hz Sensor button lights up For 1 mains 230V AC ...

Страница 14: ...7248 C 14 Subject to technical changes 4 6 2 Connection diagram 3 mains 400V AC Attention The operating voltage between L1 and N is 230V Higher voltages can destroy the device Smaller voltages can lead to malfunctions Sensor button lights up Mains input 3 400V 50Hz For 3 mains 400V AC ...

Страница 15: ...7248 C 15 Subject to technical changes 4 6 3 Connection diagram 3 mains 230V AC Attention The operating voltage between L1 and N is 230V Higher voltages can destroy the device Smaller voltages can lead to malfunctions Sensor button lights up Mains input 3 230V 50Hz For 3 mains 230V AC ...

Страница 16: ...ton connection diagram N L1 Sensor button lights up Rotary switch MODE A Sensor button 1 3 lights up BUS control line 2x 0 5mm2 max 30m Feedback via DOUT1 4 DOUT1 Pump ON DOUT2 Fault DOUT3 Enable Converter box 3 0 Art No 61405 valid from SW 0 23 Requirement SW 0 47 or higher Mains input Example 3 400V the following are also possible 3 230V 1 230V ...

Страница 17: ...lue for undercurrent error Duration for undercurrent error s 60 Disable time s 2 RELAY OUTPUTS Pump on und Malfunction Switching voltage V AC max 276V AC Switching current A AC max 3A AC PIEZO BUTTON Voltage on button and LED V DC 22 5 25 5V DC Switching threshold for button V DC 10 14V DC LED current mA DC max 30mA DC AIR BUTTON Hose length m max 20m Rubber hose inside diameter ø2 25x1mm Male cou...

Страница 18: ...dware version SW Software firmware version SN Serial number Abbreviation for functional enable S Control box PN Air button Z Time relay E External piezo BESGO 2 way valve DR 3 phases L1 L2 L3 N PE AC 1 phase L1 N PE IN Rated pump current PN Rated motor power Air button Control box Time relay Mains voltage Output 3 phase current max Output Protection class Operating voltage IN max ...

Страница 19: ...Schmalenberger GmbH Co KG D 72072 Tübingen Germany Control box Control NT Version 27248 C 19 Subject to technical changes 7 Service notes Who When What ...

Страница 20: ...römungstechnologie Fax 49 0 7071 70 08 10 Im Schelmen 9 11 Internet www fluvo de D 72072 Tübingen Germany E mail info schmalenberger de 2018 Schmalenberger GmbH Co KG All rights reserved Manual is subject to changes Control box Control NT Version 27248 C ...