OPERATING INSTRUCTIONS
57
C2 rondo
Version: 27200 - D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4.11.2
Face plate assembly installation / Concrete-liner pool
Cut out the pool liner to fit. Remove the mounting protection film (C). Place the clamp
gasket (39.1) between the installation housing and the liner and screw the clamp ring (30)
to the installation housing using the screws (74). The sealing contact faces must be clean
and smooth. After connecting the air button, put on the face plate assembly (35), this allows
the pressure connection and air connection to slide into one another. Fasten to the clamp
ring (30) with the screws (90.2).
4.11.3
Face plate assembly installation / Pre-fabricated pool
fig. 23
C
Mounting protection film
10
Suction housing
21
Switching tube
30
Clamp ring
35
Face plate assembly
39.1
Clamp gasket
74
Screw
90.2
Screw
Warning!
Make sure that there is not a kink in the switching tube (21), lay it in a loop and
do not shorten!
fig. 24
10
Suction housing
21
Switching tube
30
Clamp ring
35
Face plate assembly
90.3
Screw
After connecting the air button, put on the
face plate assembly (35), this allows the
pressure connection and air connection
to slide into one another. Fasten to the
clamp ring (30) with the screws (90.3).
Warning!
Make sure that there is not a kink in the
switching tube (21), lay it in a loop and do
not shorten!
8436
8437