34
Schleuniger CCM 1200
Wire Marking
The CCM 1200 can control an upline wire marker. Position the function-ready wire marker to the
left of the CCM 1200. The distance between the wire marker stamps (marking wheels) and the
blades on the CCM 1200 should not exceed 1 m. Connect the wire marker to the CCM 1200
using the Wire Marker connection (Figure 2, Page 23). Ensure that the cable to be marked can
move smoothly. The best way to explain how to programme a wire marking procedure is by way of
an example. So let’s produce the following cables:
20 cables, each 380 mm long, 1 marking on the right hand side 35 mm from the end of the cable,
1 marking 40 mm from the left hand side of the cable, 1 marking in the middle of the cable.
XXX
XXX
XXX
Figure 11. Practical example of wire marking
Programme step
Key
sequence
Display
In order to activate the Hotprint mode hold
down [1] when switching on the CCM 1200.
quantity
length
speed
Select the length of the cable to be cut, for
example 380 mm.
[length]
[3 8 0]
quantity
length
speed
Switch the Hotprint mode on if it is off. (If
the Hotprint mode is off a 0 appears in the
right hand side of the display).
[enter]
[1]
quantity
length
speed
Select the distance from the right end of the
cable to the centre of the marking.
[enter]
[3 5]
quantity
length
speed
BEGINN ? 35
LENGTH ? 380
END 40 mm
PRINT 0/1 1
BETWEEN 155 mm
BEGIN 35 mm
380 mm
HOTPRINT-MODE
Содержание CCM 1200
Страница 50: ...50 Schleuniger CCM 1200 Electrical Diagramm...