Schletter GmbH
as of 10/2016
PvMax3
Mounting Instructions
24
/
35
4.5.2. Fastening of the module clamps
Name
Tightening
torque (MA-Nm)
Module
arrangement
Hexagon socket screw DIN4762 M8
(20 - 35 mm)
KlickIn click component for nut M8
Square nut DIN557 M8 A4
14 Nm
H, V and Kombi
TX stud screw M8 A2 GMC
(42.5 - 55 mm)
14 Nm
H, V and Kombi
Always fasten the bolted connection by turning the bolt head! When checking
the pre-stress of the bolts, it has to be considered that constraints and frictional
forces can lead to a loss of clamping force. This was taken into consideration when
the tightening torques were determined. When a bolted connection is checked, it
must not loosen when 50% of the specifi ed tightening torque is applied.
Fig. 4.5.2.-1 (Standard module clamp)
Fig. 4.5.2.-2 (Rapid
2+