CS-8 Series DTG Rev1.3, July 2020
-16-
the
Gate output
.
Jack 5
selects via a control voltage between "Gate" mode
and "Delay" mode. +5 V selects "Gate", 0 V selects "Delay". It lies via an internal
switching contact at +5 V and, so, pre-selects normally the "Gate" mode. As
soon as a cable is plugged in, even if the other end is open, the "Delay"
function becomes active. Fig. 4 describes best the functional principal of the
Gate mode.
Voltage
time
Gate Reset
Gate in
+5 V
+5 V
+5 V
Gate
time
Gate Out
time
time
Fig. 4 Gate mode
As one can see, th e Gate length is always th e same, independently of th e
duration of the input Gate signal at
jack 1
. The
Gate-Reset
is only active in
Gate mode. The referring
jack 7
is connected internally via a switching contact
to
jack 8
(
Envelope-Gate
input), namely
inverse!
Th e reason for th at will be
explained further down. For independently work of the Gate in Gate mode
from the envelope generator it needs a
plug into
jack 7
to untie this internal
connection.
Fig. 5 shows the functional principal of the Gate in Delay mode. If one can see,
no output will be generated when the incoming Gate is shorter than the Delay
time. So, it's a delayed 0 V
→
+5 V transition as long the incoming Gate is held
beyond the delay time.