MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING
Page 9
3
User menus
This chapter discusses all settings in the user menu.
3.1
24-hour overview
24 uur grafiek
Open grafiek
This opens a 24-hour temperature and ventilation graph. Different graphs can be selected with the icons on
the right side of the graph. The graph can be closed by pressing the 'X' icon in the upper right corner of the
graph.
Yesterday's measurements are shown with a thin orange graph line. A thicker blue graph line shows today’s
measurements to the present time.
3.2
Target temperature
Streef-
temperatuur
°C
Input range: 0.0°C - 50.0°C [factory value: 20°C]
Here you can set the desired temperature for the department.
3.3
Minimum ventilation
Minimum
ventilatie
%
Input range: 0% - 100% [factory value: 10%]
Here you can set the desired minimum ventilation. This is the ventilation rate when the room temperature is
equal to or lower than the set temperature.
3.4
Maximum ventilation
Maximum
ventilatie
%
Input range: 5% - 100% [factory value: 100%]
Here you can set the desired maximum ventilation. This is the ventilation rate when the room temperature
has reached the end of the bandwidth.