SAFETY PRECAUTIONS

1.

Check the heater thoroughly for damage.  DO NOT
operate a damaged heater.

2.

DO NOT modify the heater or operate a heater which
has been modified from its original condition.

3.

Use only propane gas.

4.

Use only VAPOR WITHDRAWAL propane supply.  If
there is any question about vapor  withdrawal, ask
your propane dealer.

5.

Mount the propane cylinders vertically (shutoff valve
up).  Secure them from falling or being knocked over
and protect them from damage.

6.

Locate propane containers at least 7 ft. from the
heater and do not direct exhaust toward containers.

7.

Use only the hose and regulator assembly provided
with the heater.  Inspect hose assembly before each
use of the heater.  If there is excessive abrasion or
wear, or hose is cut, replace with hose assembly
listed on parts list before using heater.

8.

For indoor use only.  Area must be well ventilated.
Provide minimum openings of 2 sq. ft. near the floor
and 2 sq. ft. near the ceiling (also see "Operating
Precautions").

9.

If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has
been located and corrected.

10.

Install the heater such that it is not directly exposed to
water spray, rain and/or dripping water.

11.

Maintain minimum clearance from normal combust-
ible material (like paper) as follows:
floor-0 ft.;outlet-6 ft.; sides-1 ft.; top-3 ft. Locate 10 ft.
from canvas or plastic tarpaulins or similar coverings
and secure them to prevent flapping or movement
due to wind action.

12.

Operate only on a stable, level surface.

13.

Do not use with ductwork. Do not restrict inlet or exit.

14.

Use only the electrical power specified.  The electri-
cal connection and grounding must comply with
National Electrical Code - ANSI/NFPA 70.

15.

Use only a properly grounded 3-prong receptacle or
extension cord.

16.

Do not move, handle or service while hot or burning.

17.

Use only in accordance with local codes or, in the
absence of local codes, with the Standard for the
Storage and Handling of Liquefied Petroleum Gases
ANSI/NFPA 58-1998.

WARNING: FIRE, BURN, INHALATION, AND EX-

PLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH
AS BUILDING MATERIALS, PAPER OR CARDBOARD, A
SAFE DISTANCE AWAY FROM THE HEATER AS RECOM-
MENDED BY THE INSTUCTIONS NEVER USE THE HEATER
IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR
AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS
GASOLINE, SOLVENTS, PAINT THINNER, DUST PAR-
TICLES OR UNKNOWN CHEMICALS.

OPERATING PRECAUTIONS

This is a propane, direct-fired, forced air heater.  It's intended
use is primarily temporary heating of buildings under construc-
tion, alteration or repair.

WARNING

NOT FOR HOME OR RECREATIONAL VEHICLE USE

Propane is heavier than air.  If propane leaks from a connection
or fitting, it sinks to the floor, collecting there with the surround-
ing air, forming a potentially explosive mixture.  Obviously,
propane leaks should be avoided, so set up the propane supply
with utmost care.  Leak check new connections or reconnections
with a soap and water solution and follow all connection
instructions herein.  Also, ask your propane dealer for advice
on the propane supply installation and ask him to check it if
there are any questions.

Direct-Fired means that all of the combustion products enter
the heated space.  Even though this heater operates very
close to 100 percent combustion efficiecy, it still produces
small amounts of carbon monoxide.  Carbon monoxide (called
CO) is toxic.  We can tolerate small amounts but not a lot.  CO
can build up in a heated space and failure to provide adequate
ventilation could result in death.  The symptoms of inadequate
ventilation are:

headache
dizziness
burning eyes and nose
nausea
dry mouth or sore throat

So, be sure to follow advice about ventilation in these operating
instructions.

Forced Air means that a blower or fan pushes the air through
the heater.  Proper combustion depends upon this air flow;
therefore, the heater must not be revised, modified or oper-
ated with parts removed or missing.  Likewise, safety systems
must not be circumvented or modified in order to operate the
heater.

When the heater is to be operated in the presence of other
people the user is responsible for properly acquainting
those present with the safety precautions and instruc-
tions, and of the hazards involved.

!

Page 2

Содержание 150-FAST

Страница 1: ...IONS BEFORE YOU OPERATE THIS HEATER RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE PROPANE CONSTRUCTION National Riverside Universal MODEL SPC 150T SPC ALL PRO FORCED AIR 150 000 BTU HR HEATER SPECIFICATIONS 150 Type of Gas For Use with Propane Gas Only InputRating 150 000BTU hr FuelConsumption 7 Lbs hr Gas Supply Pressure to Regulator Max Bottle Pressure Min 5 psig Regulator Out 11 W C Fuel Orifi...

Страница 2: ...98 WARNING FIRE BURN INHALATION AND EX PLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOM MENDEDBYTHEINSTUCTIONSNEVERUSETHEHEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PAR TICLES OR UNKNOWN CHEMICALS OPERATING PRECAUTIONS This is a p...

Страница 3: ...OL fitting of hose and regulator assem bly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder s valve outlet and securely tighten with a wrench 4 Connect the hose to the heater by rotating the hose fitting clockwise 5 Securely tighten all gas connections 6 Open the cylinder s gas valve and check all gas connections with a soap and water solution DO NOT USEAF...

Страница 4: ...33 3133 Support Motor Strap 2 7744 7744 Label Model Operating Instructions 1 15 1561 1561 Motor Assembly 1 6374 6374 Label Electrical Ground 1 16 3087 3087 Grille Inlet 1 7789 7789 Label Wiring Diagram 1 17 6225 6225 Snap Bushing 5 8 1 7067 7067 Label BTU Rating 2 18 3132 3132 Saddle Motor Support 1 6383 6752 Label Logo 2 19 6152 6152 Hose Assembly 1 7743 7743 Manual Operating Instr 1 20 6255 6255...

Страница 5: ...1959 Red 7 Flame Control Harness Terminal Block 1959 White 6 Flame Control Harness Terminal Block 1959 Black 6 Flame Control Harness Terminal Block INSTRUCTIONS FOR ORDERING PARTS All parts orders must show heater Model No Item No Part No and Description We recommend that only parts supplied by the manufacturer be used on this unit A locally purchased part may appear to be identical although in re...

Страница 6: ...eitherpartsorlaborand will be returned to you freight prepaid Please include a brief statement indicating date place of purchase the nature of the problem and proof of purchase Out of warrrantyproductsreturnedtotheServiceDepart mentwillberepairedwithachargeforpartsandlaborand will be returned to you freight collect TECHNICAL INFORMATION HOW MUCH HEAT DO I REQUIRE For economy it is important to mat...

Отзывы: