L’innovation française depuis 1965
P.4
Seen from above
Left side view
Right side view
CAN BUS
TYCO 21-pin
Connector
STATUS LED
Страница 1: ... User Manuel Troubleshooting Guide BLOC 11 Ref 41 70521 00 XXX XXX Acknowledgement P 2 Safety Warnings P 2 Accessories Associated references P 2 Equipment description P 2 Technical characteristics P 3 Electrical characteristics P 3 Description of the markings used P 3 Installation instructions P 5 Connection P 5 Wiring P 6 Terms and conditions P 7 Warranty terms P 7 ...
Страница 2: ...carefully This manual explains how to use and install the product in accordance with its intended use Safety Warnings WARNING Do not disassemble the device Any contact with the product s internal components can cause injury In the event of a malfunction only a qualified technician is authorised to repair the device WARNING In the event of impact If the product falls or undergoes heavy impact immed...
Страница 3: ...L CONDITIONS Indoor use Altitude up to 2000m Operating temperature 0 to 50 C Relative humidity 0 to 93 non condensing Protection index IP20 MOUNTING 4 screws MOUNTING DISTANCE 100 x 59 mm WEIGHT 0 19 Kg STANDARDS EN 60945 FIRMWARE VERSION V8 00 or higher DIMENSIONS LxWxH 160 x 95 x 50 mm INPUT RATED VOLTAGE VDC 8 32 VDC SELF CONSUMPTION 45 mA MAXIMUM CURRENT PER OUTPUT 1A MAXIMUM CUMULATIVE CURREN...
Страница 4: ...nnovation française depuis 1965 P 4 L innovation française depuis 1965 Seen from above Left side view Right side view CAN BUS CAN BUS TYCO 21 pin Connector CAN BUS CAN BUS TYCO 21 pin Connector STATUS LED ...
Страница 5: ... The product must be installed away from heat and humidity WARNING Connection disconnection with power on Do not perform connection or disconnection with power on INPUT OUTPUT POWER SUPPLY Type of connection Cross section MCP2 8 21Pts BROWN housing connectors Ref Scheiber 0E CON1430 Ref Tyco 8 968975 1 MCP2 8GEH21P MCP2 8 Receptacle 0 5 1 0mm2 tinned Ref Scheiber 0E CLP360 Ref Tyco 1 968849 1 Extr...
Страница 6: ...mentary switches N 4 13 S5_NO NO Contact Relay n 5 14 S5_C Common relay contact n 5 15 E5_NUM_PLUS Plus digital input for momentary switches N 5 16 S6_NO NO Contact Relay n 6 17 S6_C Common relay contact n 6 18 E6_NUM_PLUS Plus digital input for momentary switches N 6 19 BAT Power supply input 8 32VDC 20 CODING Coding input 21 MASS Battery mass Wiring 1 2 Connect to each connector either a CAN con...
Страница 7: ... to the article 1641 and followings of the Civil Code Repairs and replacement of the equipment during the warranty period do not change terms or time of this warranty which is of 2 years Repairs and replacement of the faulty parts under warranty are made only on presentation of the invoice which certifies the warranty beginning date WARRANTY DOES NOT APPLY This warranty can not be applied in case ...
Страница 8: ...2 Bellevue 85120 Saint Pierre du Chemin France Phone 33 0 2 51 51 73 21 sav scheiber fr www scheiber fr Question contact scheiber fr Problem sav scheiber fr L innovation française depuis 1965 ...