background image

Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual

9

Issued: 21.06.2010

811.592 BA / EN

4 Application and function

The Elektroblock EBL 220-4 A and EBL 220-4 with OVP is the central power

supply unit for all 12 V consumers connected to the electrical system of the

motorhome or caravan. It is normally fitted inside a cabinet or a stowage

space and can be accessed from the front to change a fuse.

The electroblock EBL 220-4 with OVP is suitable for all cases of application

in which the danger of overvoltage is especially large. This can e. g. be

lightning strikes in the public mains, generator operation, bad electronic

installations or trips to foreign countries.

For this in the electroblock an overvoltage protection is fitted in internally

between the mains connection and the loading module.

EBL 220-4 with OVP

DT/LT ...

ST ...

+

--

+

--

Control panel

Control and

display panel

Electroblock

230 V AC

12 V consumer

Living area battery

Starter battery

(special equipment)

Lighting

Pump

Heater

etc.

LR ...

Solar control

(accessory)

LAS...

Auxiliary charger

(accessory)

EBL 220-4

Fig. 2

Onboard power supply system

The Electroblock EBL 220-4 A consists of:

F

A charging module for recharging all of the connected batteries

F

The complete 12 V distribution system

F

The fuses for the 12 V power circuits

F

A battery monitor module

F

Other control and monitoring functions

In addition the Electroblock EBL 220-4 with OVP consists:

F

Overvoltage protection OVP, disconnecting the electroblock in case of

detecting an overvoltage of the 230 V supply.

A DT ... or LT ... control and switch panel must be connected up to run it.

For additional functions an ST ... switch panel (optionally) can be connected.

These devices control the electrical functions in the motorhome’s living area

as well as the accessories.

Connection options are available for up to two additional battery charging

units and a solar charger.

Overvoltage protection

OVP

Modules

System devices

Содержание Electroblock EBL 220-4 A

Страница 1: ... 220 4 A EBL 220 4 with OVP Table of contents 1 Safety Information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Starting the system 3 3 2 Changing the battery 4 3 3 Operating faults 5 3 4 Shutting down the system 7 3 5 Closing down the system 7 4 Application and function 9 4 1 Battery functions 10 4 2 Additional functions 11 5 Maintenance 12...

Страница 2: ... faults which may have an adverse effect on personal safety or device safety must be rectified immediately by qualified personnel Y DANGER 230 V mains voltage carrying parts Danger of death due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate from the power supply F Ensure that n...

Страница 3: ...not require daily operation Initial setting is only needed after the type of battery lead acid or lead gel has been changed or during commissioning or when upgrading with acces sories see Chapter 3 2 and installation instructions for details 3 1 Starting the system Y ATTENTION Electroblock can be set up incorrectly The connected devices will be damaged Therefore prior to starting F Make sure the l...

Страница 4: ...t itself Y ATTENTION Battery buffer function missing The connected devices will be damaged F Never run the solar charger without a battery being connected 3 2 Changing the battery Y ATTENTION Wrong battery type or incorrectly connected battery Will damage the battery or the devices connected up to the Electroblock F Batteries shall only be changed by qualified personnel F Follow the instructions o...

Страница 5: ...tch to the correct position Disconnect the Electroblock from the mains before resetting the battery selector switch 1 Fig 1 Battery selector switch Move the battery selector switch Fig 1 Pos 1 into the relevant position using a thin object e g ball point pen F Lead gel battery Set the battery selector switch to Lead gel Gel F Lead acid battery Set the battery selector switch to Lead acid Säure Sta...

Страница 6: ... 13 3 V Defective Electroblock Call customer service Living area battery over loaded during 230 V operation battery voltage permanently above 14 5 V Defective Electroblock Call customer service Starter battery is not No mains voltage Switch the cut out in the Starter battery is not charged during 230 V No mains voltage Switch the cut out in the vehicle back on check the g g operation battery volta...

Страница 7: ...ergency plug Have the DT LT control and switch panel repaired Y If the device becomes too hot due to excessive ambient temperature or lack of ventilation the charging current is automatically reduced How ever always prevent the device from overheating Y If the automatic shutdown mechanism of the battery monitor is triggered fully charge up the living area battery Y For faults regarding the D signa...

Страница 8: ... period i e during the winter The system is equipped with a battery isolator that completely isolates the living area battery electrically from the vehicle Battery isolation is activated from the DT LT control and switch panel see DT LT control and switch panel instruction manual 12 V main switch on the DT LT control and switch panel must be switched off Activate battery isolation on the DT LT con...

Страница 9: ... display panel Electroblock 230 V AC 12 V consumer Living area battery Starter battery special equipment Lighting Pump Heater etc LR Solar control accessory LAS Auxiliary charger accessory EBL 220 4 Fig 2 Onboard power supply system The Electroblock EBL 220 4 A consists of F A charging module for recharging all of the connected batteries F The complete 12 V distribution system F The fuses for the ...

Страница 10: ...ching option provided by the battery selector switch ensures opti mum charging of the two different types of battery lead acid and lead gel The battery monitor of the control and switch panel DT LT with dynamic voltage wave continuously monitors the living area battery It switches off earlier with small discharge currents than with large ones This enhances the total discharge protection Monitoring...

Страница 11: ... Y This device is exclusively designed for installation into a vehicle 4 2 Additional functions This relay supplies the AES compressor refrigerator with power from the starter battery when the vehicle engine is running and the D connection is live An AES compressor refrigerator is powered by the living area battery when the vehicle engine is switched off This feature provides an automatic trickle ...

Страница 12: ...switch panel ST is an optional extension for the electroblock EBL 220 4 Via three buttons consumers can be switched off individually If the switch panel ST is not available a strapping plug must be connec ted to block BL11 of the electroblock EBL 220 4 also see block diagram appendix F 5 Maintenance The electroblock requires no maintenance Clean the Electroblock using a soft moist cloth and mild d...

Страница 13: ...nhänger zwecks Anpassung an den techni schen Fortschritt F RICHTLINIE 2005 83 EG DER KOMMISSION vom 23 November 2005 zur Änderung der Anhänge I VI VII VIII IX und X der Richtlinie 72 245 EWG des Rates über die Funkentstörung elektromagnetische Verträglichkeit von Kraftfahrzeugen zwecks ihrer Anpassung an den technischen Fortschritt F RICHTLINIE 2004 108 EG DES EUROPÄISCHEN PARLAMENTS UND DES RATES...

Страница 14: ...he event the DT control and display panel is defective the electroblock can continue to be used if the emergency plug if inserted into BL 10 and BL 13 C Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 88677 Markdorf Germany Phone 49 7544 9577 16 Email kundendienst schaudt gmbh de Opening hours Mon to Thur 08 00 12 00 13 00 16 00 hours Fri 08 00 12 00 hours Returning a defec...

Страница 15: ..._____________________ Article no _______________________ Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No Is over voltage protection OVP connected upstream Yes No The following fault has occurred please tick Electrical consumers do not work which please specify below Switching on and off not possible Constant fault Intermittent fault...

Страница 16: ... area battery sensor D 10 Mains connection 11 Battery selector switch for lead gel lead acid 12 BL 13 connections for DT LT control and switch panel 13 Switch D active high D active low 14 BL 10 connections for DT LT control and switch panel 15 BL 11 connections for ST switch panel or strapping plug 16 BL 8 connections for step TV aerial and other consumers 17 Flat vehicle fuse for solar TV aerial...

Страница 17: ...anel Lighting negative MS relay 2 On Mains indicator Living area battery negative sensor MS relay 2 Off Living area battery sensor Lighting Pin strip MSFQ 0 12V BL 13 Shunt battery Shunt consumer Starter battery MS main switch relay 1 On MS relay 1 Off Solar module WB signal SB signal SB Solar module LRS 1214 MNL socket 3F BL 5 WB Negative Fuse for compressor AES refrigerator only Refrigerator D B...

Страница 18: ...Electroblock EBL 220 4 A EBL 220 4 with OVP instruction manual 18 Issued 21 06 2010 811 592 BA EN This page intentionally left blank ...

Отзывы: