Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
3
Issued: 21.06.2010
811.592 BA / EN
2 Introduction
Y
This device is exclusively designed for installation into a vehicle.
This instruction manual contains important information for the safe operation
of equipment supplied by Schaudt. It is imperative that you read and follow
this safety information.
The instruction manual should always be kept in the vehicle. All safety infor-
mation must be passed on to other users.
Y
This device is not intended to be used by persons (including children)
with limited physical, sensory or mental aptitude or lack of experience
and/or knowledge unless they are supervised by a person responsible for
their safety or have received instruction from this person as to how the
device is used.
Children are to be supervised so as to ensure they do not play with the
device.
3 Operation
The Electroblock is operated solely from the DT/LT ... control and switch
panel connected to it and via the ST ... control panel (if fitted).
The EBL 220-4 Electroblock does not require daily operation.
Initial setting is only needed after the type of battery (lead-acid or lead-gel)
has been changed or during commissioning or when upgrading with acces-
sories (see Chapter 3.2 and installation instructions for details).
3.1 Starting the system
Y
ATTENTION!
Electroblock can be set up incorrectly!
The connected devices will be damaged. Therefore prior to starting:
F
Make sure the living area battery is connected.
F
You must ensure that the battery selector switch (Fig. 3, Pos. 11) is
set to the correct position for the type of battery being used.
F
You must ensure that the AES fuse (Fig. 3, Pos. 6) is only inserted if
an AES refrigerator is connected to the system. Otherwise, the living
area battery may get totally discharged. Battery damage is possible.
F
You must ensure that the switch for the number of auxiliary chargers
(Fig. 3, Pos. 18) is set in the correct position.
³
Deactivate battery isolation on the DT/LT ... control and switch panel (see
instruction manual for the associated control and switch panel).
³
After deactivating the battery isolation or after changing batteries: Turn
on the 12 V main switch on the DT/LT ... control and switch panel briefly
to start up the consumers.
12 V main switch
(on DT/LT ... control and
switch panel)