SDT-0054-00EN
Situation: 15.06.2005
7
Instruction Manual Electrobloc EBL 99 G
6.3
Battery monitor
Automatic disconnector
The battery monitor compares the voltage of the living area battery to a refer-
ence voltage. As soon as the battery voltage falls below 10.5 V, all 12 V con-
sumers are switched off via the main switch relays 1 and 2. Only the frost pro-
tection valve is still powered. The automatic disconnector is not triggered by
short-term low voltage (less than 2 seconds), caused by high current when
switching on consumers.
If an overload or an insufficiently charged living area battery causes the volt-
age to fall so low that the automatic disconnector is triggered, any consumers
which are not essential should be switched off.
You may be able to switch on the 12 V power supply for a short time. To do
this, switch on the 12 V main switch on the control and switch panel.
However, if the battery voltage remains below 11.0 V, you cannot switch the
12 V power supply back on.
Fully charge up the living area battery as soon as possible. For more informa-
tion see the description of battery voltage.
7
Maintenance
The Electrobloc requires no maintenance.
Cleaning
Clean the Electrobloc with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances.
Do not allow fluid to penetrate the inside of the Electrobloc.
8
Shutting down the system
Disconnecting the living
area battery from the 12 V
power supply
Disconnect the living area battery from the 12 V power supply if you are not
going to use the motorhome for a lengthy period (for example during the
winter).
Switch off the 12 V main switch on the control and switch panel.
Set the battery cut-off switch on the Electrobloc to "Batterie Aus" (battery
off).
Remove the plug "+ Solarzelle" (+ Solar Module) on the solar charge reg-
ulator, if the battery is going to be removed.
Pull out the fuse for the AES refrigerator.
W
Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
24 hours with a 160 Ah battery.
W
Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, please first take off the pos-
itive lead "+ Solarzelle" (+ Solar Module) on the solar charge regulator.
W
When the living area battery is separated from the Electrobloc by the bat-
tery cut-off switch, the frost protection valve of the heater system opens.
Water may be lost. For more information, see the instruction manual of the
heater system.