background image

10

Situation: 15.06.2005

SDT-0054-00EN

Instruction Manual Electrobloc EBL 99 G

11

Customer service

Customer service address

Schaudt GmbH, Elektrotechnik & Apparatebau
Daimlerstraße 5
88677 Markdorf
Germany

Phone: +49 7544 9577-16

Email: [email protected]

Sending in the device

Returning a defective device:

„

Always use well-padded packaging.

„

Fill in and enclose the fault report, see section 13.

„

Send it to the addressee delivered free.

Disposal instruction

When the product service life is over, dispose of the device in accordance with 
the applicable regulations.

12 V power supply in the 
living area does not work

12 V main switch for the liv-
ing area battery is 
switched off

Switch on the 12 V main 
switch for the living area 
battery

Battery cut-off switch is 
switched off

Switch on the battery cut-
off switch

Defective fuse or wiring

Have the fuse and wiring 
checked

Defective Electrobloc

Call customer service

Fault

Possible cause

Remedy

W

If the device becomes too hot due to excessive ambient temperature or 
lack of ventilation, the charging current is automatically reduced. However, 
always prevent the device from overheating.

W

If the automatic shutdown mechanism of the battery monitor is triggered, 
fully charge up the living area battery.

Opening hours

Mon to Thu
Fri

8 to 12 a.m., 1 to 4 p.m.
8 to 12 a.m.

Содержание 911.417

Страница 1: ...struction manual Electrobloc EBL 99 G Type no 911 417 Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Suitable accessories not supplied 4 5 Electrical data 4 6 Operation 5 7 Maintenance 7 8 Shutting down the system 7 9 Changing the battery 8 10 Technical faults possible causes and remedies 9 11 Customer service 10 12 Block diagram for specialist work...

Страница 2: ...fied personnel W Failure to comply with this sign may lead to the endangerment of per sons W Failure to comply with this sign may damage the device or the connected consumers W This sign indicates recommendations or special features W The electrical system of the motorhome or the caravan has to meet current DIN VDE and ISO regulations Manipulations of the electrical system will endanger the safety...

Страница 3: ... get totally discharged Bat tery damage is possible W An incorrectly set battery selector switch damages the living area battery W Disconnect the Electrobloc from the mains before adjusting the battery selector switch W If the living area battery is separated from the Electrobloc using the 12 V main switch at the control and switch panel the frost protection valve of the heater system opens Water ...

Страница 4: ...s 12 Battery cut off switch 4 Suitable accessories not supplied Control and switch panel P IT 20 2 IT 20 3 IT 95 IT 901 IT 991 IT 992 IT 993 P LT 410 LT 99 LT 993 and their variants Auxiliary charging unit Schaudt battery charging unit type LAS with up to 18 A charge current Additional 2 pin charging cable lengths supplied on request Solar charge regulator Schaudt solar charge regulator type LR fo...

Страница 5: ...cut off switch or after changing batteries Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers Shutting down the system Set the battery cut off switch to Batterie Aus battery off W Blown fuses must only be replaced when the cause of the fault is known and eliminated W Never bridge or repair fuses W Danger of burning Blown fuses must only be changed on a...

Страница 6: ...frigerator P Spare 4 For more information see the instruction manual of the control and switch panel 6 2 Additional functions Automatic switch function for AES compressor refrigerator 7KLV UHOD VXSSOLHV WKH 6 FRPSUHVVRU UHIULJHUDWRU ZLWK SRZHU IURP WKH VWDUWHU EDWWHU ZKHQ WKH YHKLFOH HQJLQH LV UXQQLQJ DQG WKH FRQQHFWLRQ LV OLYH An AES compressor refrigerator is powered by the living area battery w...

Страница 7: ...rgent Never use spirit thinners or similar substances Do not allow fluid to penetrate the inside of the Electrobloc 8 Shutting down the system Disconnecting the living area battery from the 12 V power supply Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a lengthy period for example during the winter Switch off the 12 V main switch on th...

Страница 8: ...er changing batteries Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers W The living area battery can also be charged using the internal charger module an auxiliary charging unit the solar charge regulator and the alter nator when the battery cut off switch is switched off W Batteries may only be changed by qualified personnel W Follow the instruction...

Страница 9: ...s not charged during 230 V operation battery voltage constantly below 13 0 V No mains voltage Switch on the automatic fuse in the vehicle Have the mains voltage checked Defective Electrobloc Call customer service Living area battery is not charged during mobile operation battery voltage below 13 0 V Defective alternator Have the alternator checked No voltage at D input Have the fuse and wiring che...

Страница 10: ...gulations 12 V power supply in the living area does not work 12 V main switch for the liv ing area battery is switched off Switch on the 12 V main switch for the living area battery Battery cut off switch is switched off Switch on the battery cut off switch Defective fuse or wiring Have the fuse and wiring checked Defective Electrobloc Call customer service Fault Possible cause Remedy W If the dev...

Страница 11: ...LQGLFDWRU 1HJDWLYH VHQVRU EDWW 6HQVRU EDWW 6 EDWW DWWHU FXW RII VZLWFK 2II 5HIULJHUDWRU UHOD 1RW DVVLJQHG 1RW DVVLJQHG 1RW DVVLJQHG LUFXLW ERDUG 3 D 7 SH QR 5HIULJHUDWRU UHOD 01 VRFNHW FDS EORFN 01 VRFNHW FDS EORFN HDFK PPð PD P 6HQVRU 1HJDWLYH VHQVRU URVW SURWHFWLRQ YDOYH 6 IRU UHIULJHUDWRU HDWHU LQSXW 1HJDWLYH 6 IRU UHIULJHUDWRU ORRU OLJKW VWHS 01 VRFNHW FDS EORFN RPSUHVVRU 6 UHIULJHUDWRU 01 VRF...

Страница 12: ... completed fault report There is the following defect please tick Other remarks Device type Type no EBL 99 G 911 417 Battery not being charged during power operation Battery not being charged during mobile operation The following electrical con sumers do not work Malfunction of control and switch panel Tank Voltage Current Constant fault Temporary fault loose con tact ...

Отзывы: