background image

SCHARTEC

a trademark of 

bau-shop-24 GmbH 

Fritz-Müller-Strasse 11

9

73730 Esslingen

Germany

WEEE Reg. Nr.: DE90317979

BattG Reg. Nr.: 21008776

Schartec 

One-Way 

Infrared 

Mini

-

Photocell

Technology: 

Infrar

ed

Range

:

 

up to 15 m (rain or fog can reduce the range by

up to 30%)

Protection Class

IP 45

Power Supply

12-24 V DC/AC

Wave Length

940 nm

Working Current

:

 

Sender ≤

15 mA – 

Receiver

 ≤

30 mA

Working Temperature

:

 -

2

0°C - +60°C

Relay Contact

:

 1 A max. 3

0

 V

/ DC

Dimensions

:

 

73

 x 

43

 x 2

5

 mm

Article Number

:

 ST

2

0

1

00

8

Model Number

:

 

SPCM

WARNING!

Safety Instructions

Please read the instructions completely and carefully.

Make sure the power supply of the opener or operator has been removed  before connecting the photocell.

The photocell is not approved for use on life-threatening machines or devices. The photocell serves only as

an additional safety device.

Please use the photocell only within the specified range.

Installation

The photocell should be installed more than 20 cm above the ground and the distance between transmitter and

receiver must be more than 0.5 meter.

Avoid direct sunlight on transmitter and receiver and other direct light irradiation.

Avoid other light barriers within easy reach.

Make sure that the transmitter and receiver are firmly fastened.

DANGER! Remove the power supply of your opener / operator.

 Connect the power supply (12-24 V AC/DC)

to the provided terminals on the transmitter and receiver.

Look in the manual of your opener / operator to see if the drive has a 'normally open contact' or 'normally closed

contact'.

o

If the drive has a 'Closer Contact', connect the NC and COM terminals with the intended terminals to your

opener / operator.

o

If the drive has a 'Opener Contact', connect the NO and COM terminals with the intended terminals to

your opener / operator.

o

The terminals on the drive where you connect a photocell are dependent on the opener/operator

manufacturer.

Restore the power supply after checking the correct connection of the photocell. 

If the LED of the transmitter

lights up, then the transmitter and receiver are not aligned correctly.

 Align transmitter and receiver correctly

so that the LED is no longer lit.

Receiver

Sender

Infrar

ed

Indicator

Photocell 