Camera Control and Performing a Scan
19
Instruction Manual
SK1024U3HU
shar
ed_CameraContr
ol(3b)_Sync-ModV_USB3_ML.indd
Instruction Manual SK1024U3HU © 2019-07 E
• To configure synchronization, open the
Camera
Control
dialog. [F4]
• Within the
Synchronization
frame, select one of
the numbered line synchronization modes.
• Within the camera, the trigger control stage
is followed by a divider stage with which the
trigger frequency can be divided by integer
dividers. Enter the division ratio in the
Divider
field.
• Select the
Frame Sync
check box to activate
frame synchronization. In the
Delay
field, enter
the delay time in milliseconds.
Clock
Select
AD
Converter
Exposure
Time
Advanced
Sync Control
SyC 2
SynC A
SynC B
SyC 0,1
Output
Format
Select
CCD
Sync
Select
Pixel
Counter
Shading
Corr.
Look Up
Table
(LUT)
Line Sync A
CCLK
pixel clock
Oscillator
pixel
adress
DVAL
M0
M1
M3
M4
M4
video
video
D[0-11]
(monochrome cameras)
R[0-7], G[0-7], B[0-7]
(RGB cameras)
trigger
Restart
SOS
discharge
Line Sync B
LVAL
Camera
Interface
SynC 3...7
Sync
Divider
M3
Region of
Interest
(ROI)
pixel clock
~~~
Functional diagram of the Camera Control System
Camera Control dialog