16
BA 67
Schaeffler Technologies
Lubricators CONCEPT4
Planning external control
with PLC
The lubricator must be integrated into an external controller (PLC)
for operation. The lubricator dispenses the required lubricant
quantity via various input signals. Remote monitoring is possible as
a function of the output signals for the purpose of querying the fill
level of the cartridge and any error messages.
For further information on the control signals, see page 17.
Bleeding the lubricator
Activate the function FIL via the external controller (PLC) using
the 12-seconds signal.
The lubricator delivers 20 lubricant doses per outlet.
The total duration for carrying out the function FIL is
approx. 12 minutes per pump body.
NOTICE
Air in the lubricant line can damage the lubrication point due to
insufficient lubrication. Bleed the lubricator every time it is
commissioned.
Carry out the function FIL for as long as necessary until grease
emerges from the outlets. It may be necessary to carry out
the function FIL several times until lubricant emerges.
For detailed information on the 12-seconds signal (function FIL),
Содержание CONCEPT4