Schaeffler Technologies
BA 67
15
Connecting
the connection cable
The connection cable can transmit the supply voltage and control
signals.
NOTICE
A defective connection cable can damage the device.
Replace a defective connection cable immediately.
NOTICE
Failure to observe the safety regulations may result in damage
to the device. Ensure that all electrical connection work is carried
out exclusively by qualified personnel who observe the safety
regulations.
NOTICE
Exceeding the permissible connection values will cause serious
damage to the device. Observe the permissible connection values,
see page 34.
Connector assignment
Figure 9
Connecting
the connection cable
BU
WT
DC 24 V +4,8/–4,8 V
BN
BK
GND
1
2
4
1
4
3
2
3
0
016D815
0
016D815
PIN
Assignment
Colour
1
Input voltage DC 24 V +4,8/–4,8 V,
operating voltage stabilised at DC 24 V
Brown (BN)
2
Input signals for controlling
the individual pump outputs
White (WT)
3
Output, ground (GND)
Blue (BU)
4
Output signal
Black (BK)