Schaefer VersaMist PVM18 Скачать руководство пользователя страница 6

Maintenance

ELECTRICAL SHOCK HAZARD

  • Serious injury or death is possible.

  • Disconnect from electrical supply  
    before performing any  

 

  maintenance 

operations.

NOZZLES

The fog or spray pattern exiting from the nozzles should 
have an even cone shape. If this is not the case, the nozzle 
should be cleaned or replaced. Nozzle function should be 
checked regularly to assure best misting and evaporation 
performance.

To clean or replace a nozzle:

1.  Disconnect the unit from electrical supply.
2.  Unscrew and remove the nozzle.
3.  Soak in vinegar, rinse in water OR replace with    
 

new nozzle.

4.  Flush the water line to the mist hub before  

 

 

replacing nozzle.

5.  Screw the nozzle into the mist hub by hand.  
 

NO TOOLS SHOULD BE USED TO TIGHTEN  

 

THE NOZZLE.

FILTER

Filter maintenance requirements will vary with changing 
water conditions. The filter should be inspected frequently 
and changed as needed. A dirty filter will restrict water 
flow to the pump and can cause permanent damage.

SYSTEM DRAIN / STORAGE

When it is time to store the VersaMist or take it out of 
use for more than a few days, it is strongly recommended 
that the water be drained from the system to prevent 
calcification problems and the formation of algae. Be sure 
to empty the cooler or tank and allow it to air dry.

Clean the unit with a mild anti-bacterial solution regularly.

REPLACEMENT PARTS

REPLACEMENT PARTS

P/N 

  DESCRIPTION

TG18-3WW 

 

18" circulation fan

MK-BRASSPLUG   

Misting plug

BN12   

 

Brass replacement nozzle 0.012

TS2P 

 

 

Two-position toggle switch

PVM-PUMP2 

 

FLOJET pump

MISTHUB2 

 

Mist disk

C2500GFCI-8 

 

25 ft power cord with GFCI

0WHEEL6X134R   

Rubber wheel, 6" x 1-3/4" (for mobile tank)

WARNING

6

VersaMist User’s Manual 

©2018 Pinnacle Climate Technologies

Содержание VersaMist PVM18

Страница 1: ...is possible Retain these instructions for future reference PVM18C PVM18 WARNING CALIFORNIA PROPOSITION 65 This product can expose you to chemicals including lead which are known to the State of Calif...

Страница 2: ...porate the fog is extracted from the air causing a reduced air temperature This cooler air is then distributed to people or animals creating a direct cooling effect The performance of your misting sys...

Страница 3: ...fault circuit interruptor GFCI is attached to the power cord Includes one extra nozzle and two plugs A 14 gallon tank is included for use as water reservoir The tank includes an integrated handle and...

Страница 4: ...in tank Model PVM18LC does not include a tank Since the pump enclosure is specifically made to fit a 10 gallon Igloo cooler it must be used only with this type of cooler supplied by the user DO NOT U...

Страница 5: ...electric shock by examining the product s electrical circuit for current leakage It must be tested before each use to assure safe operation Follow these steps 1 Plug into outlet the indicator will sh...

Страница 6: ...nance requirements will vary with changing water conditions The filter should be inspected frequently and changed as needed A dirty filter will restrict water flow to the pump and can cause permanent...

Страница 7: ...defective product will be repaired or replaced at PCT s option with the defective product or component returned upon approval to PCT F O B Sauk Rapids Minnesota This warranty does not cover failure da...

Отзывы: