Schaefer VersaMist PVM18 Скачать руководство пользователя страница 4

SET-UP / OPERATION

To prepare for operation:

1.  Remove all items from cartons, remove packing  
 

material and place on a level surface. The fan is  

 

mounted on the bracket and the pump assembly is  

 

contained in the lid, so please remove carefully.

2.  Place empty cooler/tank in approximate location to be  
 

misted. Carrying a full cooler/tank will be difficult as  

 

it will weigh approximately 80 pounds.and is likely to  

 

spill out if tank is tilted back. This can also make the  

 

unit unstable and hazardous to move.

3.  Fill cooler/tank with water (and ice, if desired).
 

DO NOT FILL ABOVE HANDLE RECESS!

4.  Place the fan/pump enclosure on the cooler/tank. Be  
 

sure the intake line and filter are in the bottom of  

 

the cooler/tank.

5.  Twist the fan/pump enclosure to engage slots in tank.

Model PVM18LC does not include a tank

. Since the 

pump enclosure is specifically made to fit a 10 gallon 
Igloo cooler, it must be used only with this type of cooler, 
supplied by the user. DO NOT USE THE PVM18LC WITH 
ANY OTHER WATER RESERVOIR!

TIP HAZARD

  •  Serious injury is possible.
  •  Support weight of fan with free hand when moving  
    tank with wheels.
  •  Do not fill tank before moving.

  •  Never operate pump without water supply.
  •  If leaks are observed, turn pump off and tighten fittings by hand.
  •  Excessively hard water (high solids) can plug nozzles.
  •  A plugged filter caused by poor water quality can restrict flow to pump and cause permanent damage.
  •  Never allow “fog” from the nozzles to come in contact with surfaces. This can cause condensation and water will form  
    on those surfaces; redirect the fan to prevent this circumstance.

CAUTION

Intake line 

(filter lays in 

bottom of tank)

WARNING

Twist-On

4

VersaMist User’s Manual 

©2018 Pinnacle Climate Technologies

Содержание VersaMist PVM18

Страница 1: ...is possible Retain these instructions for future reference PVM18C PVM18 WARNING CALIFORNIA PROPOSITION 65 This product can expose you to chemicals including lead which are known to the State of Calif...

Страница 2: ...porate the fog is extracted from the air causing a reduced air temperature This cooler air is then distributed to people or animals creating a direct cooling effect The performance of your misting sys...

Страница 3: ...fault circuit interruptor GFCI is attached to the power cord Includes one extra nozzle and two plugs A 14 gallon tank is included for use as water reservoir The tank includes an integrated handle and...

Страница 4: ...in tank Model PVM18LC does not include a tank Since the pump enclosure is specifically made to fit a 10 gallon Igloo cooler it must be used only with this type of cooler supplied by the user DO NOT U...

Страница 5: ...electric shock by examining the product s electrical circuit for current leakage It must be tested before each use to assure safe operation Follow these steps 1 Plug into outlet the indicator will sh...

Страница 6: ...nance requirements will vary with changing water conditions The filter should be inspected frequently and changed as needed A dirty filter will restrict water flow to the pump and can cause permanent...

Страница 7: ...defective product will be repaired or replaced at PCT s option with the defective product or component returned upon approval to PCT F O B Sauk Rapids Minnesota This warranty does not cover failure da...

Отзывы: