SET-UP / OPERATION (continued)
1. Always operate the power mister on a level surface.
2. Fill cooler or tank with clean, fresh water (ice may be
added) each time the mister is used. Drain remaining water
after each use.
3. Aim the mister downwind for best results. If more than one
mister is used, arrange them in an arc around the area to
be misted.
4. To energize, plug the GFCI safety plug into any 120 VAC
60 Hz grounded outlet. Test GFCI per instructions below.
5. Turn the mister on using the toggle switch located on the
top of the pump enclosure.
6. Use the pull chain located on the back of the fan to choose
fan speed (OFF, LOW, MEDIUM, HIGH).
7. The mist hub located in the center of the fan is equipped
with four nozzles. The output volume of water vapor can
be reduced by replacing one or two of the nozzles with the
plugs provided.
8. The unit will mist for approximately five hours on 10
gallons of water.
GFCI TEST
The ground fault circuit interruptor (GFCI) mentioned above
provides protection from electric shock by examining the
product’s electrical circuit for current leakage. It must be tested
before each use to assure safe operation. Follow these steps:
1. Plug into outlet - the indicator will show if power is available.
2. Press the TEST button - indicator will turn off.
3. Press the RESET button. Use product only if GFCI resets.
** DO NOT USE IF TEST FAILS. **
ELECTRICAL SHOCK
HAZARD
PINCH HAZARD
TRIP HAZARD
• Serious injury or death is possible.
• Plug these units into properly
grounded receptacles only.
• Disconnect from electric supply
before filling, servicing, or
moving this equipment.
• Test GFCI before using. See
instructions at left.
• Do not carry the unit by the
motor, electric cords, hose
line, fan guard or bracket.
• Do not touch fan motor during use
or directly after; it may be hot.
• Do not operate fan without
guards in place.
• Do not insert anything into fan
guard while fan is operating.
• Unplug unit and dry any wet areas
before resetting a unit that has
tipped
over.
• Position all electric cords to lie
flat on the ground or floor.
• Never use during rain, sleet, hail,
snow or any other inclement
weather
conditions.
TEST
RESET
WARNING
5
VersaMist User’s Manual
©2018 Pinnacle Climate Technologies