EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

Alarm (zone 1). 
Customer reset 

required. 

EE 

Z1 

Z2 

Z3 

Z4 

Z5 

Z6 

Z7 

Power 

Fault 

Service 

"beep"

Tamper 

Telephone line fault 

("beep" every 5s if 

enabled). Enter access 

code  to silence 

"beep". 

EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

A tamper has 

activated and is still in 

fault. Call engineer. 

Flashing 

On 

EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

Alarm (zone 1). Call 

engineer. 

EE 

Z1 

Z2 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

Power 

Fault 

Mains fail. 

EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

A tamper has 

activated but is now 

clear. Call engineer 

EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

24Hr, Technical or PA 

zone active. Reset PA 

switch if necessary . 

EE 

Z1 

Z2 

Z3 

Z4 

Z5 

Z6 

Z7 

Tamper 

"beep" 

Power 

Fault 

Service 

Battery low - no mains. 

"beep" every 5s. Call 

engineer. 

sounder

Off 

EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

"dee - dah"

Tamper 

Fire (zone 7). Leave 

premises until you are 

sure it is safe to return. 

EE 

Power 

Z1 

Z2 

Fault 

Z3 

Z4 

Service 

Z5 

Z6 

Z7 

Tamper 

Tamper (lid, remote 

keypad, sounder, 

global tamper).Call 

engineer. 

6

496281 Issue 1 

Содержание 9449

Страница 1: ... Scantronic Leading the way in security ...

Страница 2: ...ing the sounder gives an interrupted tone and a zone light glows then a detector is being triggered maybe a door or window is open Key in your user code to stop the tone Check the indicated zone s and if possible correct the cause of the alarm Try setting the system again If the fault persists call your alarm installer Note that it may be normal for certain zone lights to glow as you walk past det...

Страница 3: ...rst Next reset the panic button then switch the alarm system bells off and reset the system see below Reset system You must reset the system before it can be used again If the Service LED is OFF then you can reset the system yourself Key in your access code again All the zone lights should go off The system is now ready for use If the Service LED is ON you must call for an engineer to reset the sy...

Страница 4: ...ck to 0000 Duress Code Your system provides a Duress Code When the system is new the code is inactive and set to To activate the code change it to a number you can remember using the same method as changing the access codes Do not use 9999 or the same number as your other access codes To inactivate the duress code change it back to If your system is connected to a central station then it will send...

Страница 5: ...he internal sounder chimes when the chime zones operate Note that the Installer must program your chime zones TELEPHONE LINE FAILURE If you see the Fault and Service LEDs flashing and a short tone every few seconds then the system has detected a fault on the telephone line connecting the system to the central station Key in your user code to stop the tone The Fault and Service LEDs will continue t...

Страница 6: ...sure the system is unset Key in 9 plus ENTER followed by your user code The keypad displays the digits of the date and time one by one on the zone and tamper LEDs The keypad sounder beeps each time the system shows a new digit The EE zone LED represents 1 and the Tamper LED represents 9 If all LEDs are off when the keypad beeps then the digit 0 zero When the keypad has completed showing the date a...

Страница 7: ...E Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper Alarm zone 1 Call engineer EE Z1 Z2 Z3 Z4 Service Z5 Z6 Z7 Tamper Power Fault Mains fail EE Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper A tamper has activated but is now clear Call engineer EE Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper 24Hr Technical or PA zone active Reset PA switch if necessary EE Z1 Z2 Z3 Z4 Z5 Z6 Z7 Tamper beep Power F...

Страница 8: ...ffort has been made to ensure that the contents of this book are correct errors and omissions excepted However neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book The contents of this book are subject to change without notice Printed and published in the U K 7 496281 Issue 1 ...

Отзывы: