Repeat for each zone 

Zone 

No. 

✽ 

OMIT 

?

?

ENTER 

"beep" 

"beep" 

Fault 

Service 

?

?

ENTER 

Zone or Tamper 

EARLIER 

LATER 

✽ 

OMIT 

TO OMIT A DETECTOR 

You may need to temporarily set the system with 
one or more detectors omitted. Key in the zone 
number followed by OMIT for all the zones you want 
to omit and then key in your user code. The system 
flashes the light(s) of the omitted zone(s) during the 
exit time and then sets. Note that you cannot omit a 
panic button, nor can you omit a 24 hour zone while 
the system is unset. 
The system will not raise an alarm if any omitted 
detector is triggered during this setting cycle. The 
system will reinstate the detector(s) and set nor­
mally the next time you set the system. 

TO SWITCH CHIME ON OR OFF 

Key in 7 then ENTER, followed by your user code to 
switch Chime on or off. When Chime is on, the 
internal sounder chimes when the chime zones 
operate. Note that the Installer must program your 
chime zones. 

TELEPHONE LINE FAILURE 

If you see the Fault and Service LEDs flashing, and 
a short tone every few seconds then the system has 
detected a fault on the telephone line connecting 
the system to the central station. Key in your user 
code to stop the tone. The Fault and Service LEDs 
will continue to flash until the telephone line fault is 
corrected. 

DISPLAYING THE LAST 10 EVENTS 

You can display the ten most recent alarms and
tampers stored in the system’s log.
Key in 8 plus ENTER followed by your user code.
The display shows the most recent zone to cause
an alarm, or lights the Tamper LED.
Key in 1 to show earlier events or 3 to see more
recent events. The display shows earlier and later
alarms/tampers. The keypads give a short tone
when you reach the end of the log.
Press OMIT or ENTER to leave the log.

KEYPAD PA 

You can start a Panic Alarm by pressing keys 1 and 
3 together on the keypad. 

496281 Issue 1 

Содержание 9449

Страница 1: ... Scantronic Leading the way in security ...

Страница 2: ...ing the sounder gives an interrupted tone and a zone light glows then a detector is being triggered maybe a door or window is open Key in your user code to stop the tone Check the indicated zone s and if possible correct the cause of the alarm Try setting the system again If the fault persists call your alarm installer Note that it may be normal for certain zone lights to glow as you walk past det...

Страница 3: ...rst Next reset the panic button then switch the alarm system bells off and reset the system see below Reset system You must reset the system before it can be used again If the Service LED is OFF then you can reset the system yourself Key in your access code again All the zone lights should go off The system is now ready for use If the Service LED is ON you must call for an engineer to reset the sy...

Страница 4: ...ck to 0000 Duress Code Your system provides a Duress Code When the system is new the code is inactive and set to To activate the code change it to a number you can remember using the same method as changing the access codes Do not use 9999 or the same number as your other access codes To inactivate the duress code change it back to If your system is connected to a central station then it will send...

Страница 5: ...he internal sounder chimes when the chime zones operate Note that the Installer must program your chime zones TELEPHONE LINE FAILURE If you see the Fault and Service LEDs flashing and a short tone every few seconds then the system has detected a fault on the telephone line connecting the system to the central station Key in your user code to stop the tone The Fault and Service LEDs will continue t...

Страница 6: ...sure the system is unset Key in 9 plus ENTER followed by your user code The keypad displays the digits of the date and time one by one on the zone and tamper LEDs The keypad sounder beeps each time the system shows a new digit The EE zone LED represents 1 and the Tamper LED represents 9 If all LEDs are off when the keypad beeps then the digit 0 zero When the keypad has completed showing the date a...

Страница 7: ...E Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper Alarm zone 1 Call engineer EE Z1 Z2 Z3 Z4 Service Z5 Z6 Z7 Tamper Power Fault Mains fail EE Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper A tamper has activated but is now clear Call engineer EE Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper 24Hr Technical or PA zone active Reset PA switch if necessary EE Z1 Z2 Z3 Z4 Z5 Z6 Z7 Tamper beep Power F...

Страница 8: ...ffort has been made to ensure that the contents of this book are correct errors and omissions excepted However neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book The contents of this book are subject to change without notice Printed and published in the U K 7 496281 Issue 1 ...

Отзывы: