Renewing the battery
Removing
1.
Disconnect the negative cable (-) from the battery (electrical cable
connected to earth).
2.
Disconnect the positive cable (+) from the battery (electrical cable
connected to starter motor).
Fitting
1.
Connect the positive cable (+) to the battery (electrical cable connected
to starter motor).
2.
Connect the negative cable (-) to the battery (electrical cable connected
to earth).
17. Every 1,200 hours:
Checking the coolant level monitor
(Optional equipment)
1.
Start the engine.
2.
Reduce the coolant level in the expansion tank to below the level
monitor.
3.
Automatic stop in the event of a fault
: The engine stops, the indicator
lamp comes on and the buzzer (if fitted) sounds if there is no fault in
the level monitor. If the function is connected via the coordinator, the
emergency stop fault code will be generated and can be read off on the
diagnostics lamp.
4.
No automatic stop in the event of a fault
: The indicator lamp comes
on and the buzzer (if fitted) sounds if there is no fault in the level
monitor.
5.
Top up coolant to the correct level, see page 31.
Do not connect the terminals
incorrectly.
This can cause serious damage
to the electrical system.
If the terminals are shorted,
sparking will occur.
Dispose of used batteries
through an authorised waste
disposal contractor.
Use a container to avoid spills
when draining the coolant.
Dispose of used coolant through
an authorised waste disposal
contractor.