17
1. Light or display fails to illuminate
TROUBLE SHOOTING
POSSIBLE CAUSE
REMEDY
No power in stove or in the control panel.
Check the power connection.
Blown fuse.
Replace the fuse.
Before seeking after-sale services, please check the list below:
POSSIBLE CAUSE
REMEDY
Inside temperature is below 130
°C.
Wait until the stove temperature reaches 130
°C
,
the flow fan will start.
2. The
f
low fan doesn’t work
POSSIBLE CAUSE
REMEDY
Auger pipe is blocked.
Clean the auger pipe, use standard pellets.
There is a problem with the connection
between feeding motor and auger.
Check if bolts between feeding auger and motor are loose
or mismatched. If so, please contact qualified technician.
3. Auger doesn’t feed pellet
TROUBLESHOOTING – ERROR CODES
SET TEMP
R T °C
TIME ON
TIME OFF
HEAT
TIMER
FIRE
LONG
TIMING
SHORT
TIMING
WORKING
MODE
DEVICE
SETTING
1.
When the power is on and display shows E1 error message,
SHORT
TIMING
TIME ON
TIME OFF
LONG
TIMING
R T °C
SET TEMP
WORKING
MODE
DEVICE
SETTING
the tempertaure probe (NTC) is failing to work.
2.
If display shows E2
SHORT
TIMING
TIME ON
TIME OFF
LONG
TIMING
R T °C
SET TEMP
WORKING
MODE
DEVICE
SETTING
, the flame sensor (thermocouple) is
failing to work.
3.
If ignition fails or fire self-extinguishes at ignition, the display
shows E3
SHORT
TIMING
TIME ON
TIME OFF
LONG
TIMING
R T °C
SET TEMP
WORKING
MODE
DEVICE
SETTING
. The pellet fire will shut off automatically.