4.

The temperature setting will now flash. Press and release the        or        button to increase or decrease the temperature setting by 
1

o

C. Press and hold the        or        button for 2 seconds or longer to increase or decrease the temperature setting by 1

o

C every 0.5 

seconds. To accept the temperature press 

OK

.

5.

Period 1 is now set for the day/s of the week that you have chosen. The LCD will display     

P2

    to indicate that Period 2 can now be 

set for the same day/s of the week. Repeat the programming process for periods 3 and 4. After program 4 is set, press     

OK

     and 

the program for the selected day/s will be set. The thermostat will now automatically turn off. Repeat the programming process for 
any other periods/days that are required.

OPERATING INSTRUCTIONS

REMOTE CONTROL INSTRUCTIONS  

...continued

Programming

Each day of the week can be programmed individually for 4 periods P1, P2, P3 and P4, making a total of 28 programmed periods. Alternatively, 
a weekday program can be set, so the same program is used for Monday-Friday. Similarly, a weekend program can be set for Saturday-Sunday. 
The entire week can also have the same program. Alternatively, a weekday or weekend program can be set with individual programs for the 
remaining days.

The suggested period settings for each day/s are:

1.

With the thermostat off, press and hold the

 

   

   button for 2 seconds or longer to initiate programming. The LCD will display  

PROG

,  

Pd

  and the time at which the thermostat is currently set. 

MO

  will flash. Period 1 can now be set.

Setting The Day Of The Week

2.

First you must choose which day of the week you wish to program

3.

Press and release the        or        button to change the day of the week to the following or previous day. Press and hold the        or        
button for 2 seconds or longer to increase or decrease the day of the week by 1 day every 0.5 seconds.

4.

The order that you can scroll through the days is as follows: MO 

 

TU 

 

WE 

 

TH 

 

FR 

 

MO, TU, WE, TH, FR 

 

SA 

 

SU 

 

SU, SA 

 

MO, TU, WE, TH, FR, SA, SU.  To accept the selected day/s of the week press    

OK 

.

Setting the period starting time

3. 

The hour and AM/PM settings will now flash. To set the P1 starting time, press and release the        or         button to increase or 
decrease the hour setting.

4.

Press and hold the        or         button for 2 seconds or longer to increase or decrease the hour setting by 1 hour every 0.5 seconds.

5.

The hour function is in 12 hour time, so please ensure that AM/PM is set correctly. To accept the hour press     

OK 

.

6.

The minute setting will now flash. Adjust the minute setting similarly, using        or        button To accept the minute press     

OK 

.

Setting The Temperature

To Begin Programming:

 

– Period 1 - Morning

 

– Period 2 - Daytime

 

– Period 3 - Evening

 

– Period 4 - Night-time

18.

Содержание AVEDUR SCGAS10

Страница 1: ...ting Aust Pty Ltd Head Office 306 South Gippsland Highway Dandenong South VIC 3175 Australia Warehouse Lot 1 Melbourne Cresent Seymore VIC 3660 Australia 61 3 5792 2388 www scandiastoves com au Model...

Страница 2: ...eaters will offer many years of reliable performance This instruction manual has been developed to ensure optimum performance from your Scandia gas space heater It s very important that you thoroughly...

Страница 3: ...AND OTHER SURFACES ARE HOT DURING OPERATION AS WELL AS DURING THE COOLING DOWN PERIOD PRECAUTION SHOULD BE TAKEN AND YOUNG CHILDREN MUST BE SUPERVISED AT ALL TIMES NOTE 1 A SLIGHT SMELL MAY BE APPARE...

Страница 4: ...NCE WITH AS4553 2008 AND AS3100 MADE IN CHINA NATURAL GAS PROPANE GAS Inlet gas pressure 1 13 kPa 2 75 kPa Outlet gas pressure 0 95 kPa 2 41 kPa Nominal maximum gas consumption 25 5 MJ h 23 0 MJ h Tur...

Страница 5: ...ck 3 Remote Control 4 App Control Module Optional accessory 5 Media Driftwood Log Set with Vermiculite 6 Propane Conversion Kit 7 Owners Manual 1 2 3 4 5 6 7 4 YOUR HEATER AT A GLANCE PROPANE CONVERSI...

Страница 6: ...443 1235 608 272 1075 952 4 4 5 86 986 20 66 FASCIA 20 1235 992 608 366 5 51 165 149 Gas Connection 1 2 Male Thread Electrical Connection HEATER PRODUCT DIMENSIONS mm...

Страница 7: ...and also include materials that are behind non combustible materials If you are not sure of the combustible nature of a material consult your local fire officials Minimum clearance for a combustible s...

Страница 8: ...height 1100mm C Rough opening depth 470mm D Rough opening width 1300mm 7 Minimum clearance for a combustible surface A Mantel height from top of the fireplace opening mm 360mm B Side Wall 80mm C Ceil...

Страница 9: ...ecified in the below table 8 INSTALLATION GUIDE FLUE INSTALLATION Vertical Vent Flue Installation Rear Vent Flue Installation Horizontal H Vertical V 1 x 90 Elbow 1 x 900mm flue pipe 1 x 90 Elbow 1 x...

Страница 10: ...l I Mechanical Air Inlet M Gas Meter P Electricity meter or fuse box Z Fan assisted appliance only ORANGE SHADING INDICATES PROHIBITED AREA FOR FLUE TERMINALS PROHIBITED AREA FOR FLUE TERMINALS 9 INST...

Страница 11: ...over 200 MJ h input up to 250 MJ h input 1500mm Appliances over 250 MJ h input 1500mm K From a mechanical air inlet including a spa blower 1500mm N Vertically below an openable window non mechanical...

Страница 12: ...stances below Glass Burner 105mm 265mm 120mm Using the glass fill the burner up to 10 15mm deep evenly spread across the tray Use 3 Lava rocks provided and place them according to the distances below...

Страница 13: ...placed in the same location as depicted in the image below Vermiculite Burner with Driftwood Default Vermiculite Burner with Pebbles Place the logs and pebbles provided in their designated location A...

Страница 14: ...r jumper inside Please refer to the compliance plate product specification table to ensure the correct injector size Please refer to the compliance plate product specification table to ensure the corr...

Страница 15: ...enly and relocate to the desired position Please note Some fascia options are heavy and may need additional assistance when handling Avedur fascia is designed to be installed against plain plaster wal...

Страница 16: ...on Media Installation Gas type conversion If required Ensure gas inlet and outlet pressure values are set according to the compliance plate Ensure that a gas leakage pressure test is carried out befor...

Страница 17: ...nd after the last button pressed Battery low indicator Indicates that battery power is below acceptable level The symbol will flash to indicate that the batteries need replacing The thermostat will re...

Страница 18: ...Of The Week Time Manual Mode 1 Press and release button If the thermostat is off pressing and releasing will turn the thermostat on to the most recently selected working mode The manual mode allows s...

Страница 19: ...uggested period settings for each day s are 1 With the thermostat off press and hold the P button for 2 seconds or longer to initiate programming The LCD will display PROG Pd and the time at which the...

Страница 20: ...ol unit CAUTION The thermostat has already been programmed with a unique code Do not attempt to teach the RF Thermostat ID code unless instructed by the manufacturer 1 With the thermostat off press th...

Страница 21: ...Select the ON button to turn on the heater Once the download has complete go to the settings menu and turn on WiFi Swipe right to increase the flame height Swipe left to decrease the flame height Man...

Страница 22: ...artment Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove any foreign obj...

Страница 23: ...isolated electrical and gas connections STEP 1 STEP 1 Remove the fascia See instructions on page 14 of this manual Remove the fascia See instructions on page 14 of this manual STEP 3 Some adjustments...

Страница 24: ...nition module and remove the pilot assembly from the firebox STEP 5 Ensure that any media has been removed from the burner To remove the burner from the firebox remove 6 screws as shown in the image b...

Страница 25: ...e fire fails to reignite contact Scandia Heating Outdoor heavy wind conditions The heater is designed to safely shutdown during heavy wind conditions If this occurs please wait until conditions subsid...

Страница 26: ...WIRING DIAGRAM 25...

Страница 27: ...AVEDUR EXPLODED DIAGRAM 26 1 2 43 29 32 8 6 9 28 3 44 48 7 26 33 31 47 40 51 49 39 18 10 17 12 37 24 34 50 25 22 42 35 38 15 11 5 16 20 19 23 27 36 14 21 52 30 13 45 41 46 4...

Страница 28: ...e 1 SPAV021 22 Modulating valve control 1 SPAV022 23 Adaptor fittings 1 2 to 5 8 4 SPAV023 24 Front component access panel 1 SPAV024 25 Component access panel firebox 1 SPAV025 26 Adaptor fittings ass...

Страница 29: ...V108 J Log 2 SPAV109 K Log 3 SPAV110 L Log 4 SPAV111 M Log 5 SPAV112 N Log 6 SPAV113 O Vermiculite SPAV114 P Crushed Glass SPAV115 28 A B C D E F G H I J K L M N O P 46 Top air deflector LHS 1 SPAV046...

Страница 30: ...ty period after the date of the original purchase such as to make the gas log fire unfit for normal home use and you comply with the requirements below regarding making a claim then subject to the exc...

Страница 31: ...South VIC 3175 Australia Warehouse Lot 1 Melbourne Cresent Seymore VIC 3660 Australia Scandia Heating Aust Pty Ltd 61 3 5792 2388 www scandiastoves com au 11 WARRANTY 30 if you are not a retail purcha...

Отзывы: