background image

A S S E M B LY

8

NAVN:

STI:

DIMENSION:

MATERIALE:

DATO:

SIGN:

Krog Iversen & Co A/S

DK-5492 Vissenbjerg©

TG.NR:

EMNE:

C:\Working Folder\Designs\DSA 12\90085003.idw

 

90085003

Målskitse for justerbare ben

09-06-11

BC

Scan DSA 12

VÆGT:

AREAL:

N/A

N/A

13

88

,6

1322

1255,4

1188,8

1122,2

1055,6

989

1388,6

0

449,6

70

136,6

203,2

269,8

336,4

403

Adjustable supporting legs

The Scan DSA 12 is supplied with adjustable supporting legs. These 

legs should be considered as providing an auxiliary function and 

can be used during construction if desired. On completion of instal-

lation, the stove must stand on the side pieces.

To adjust the height of the legs, the bottom part of the stove side 

plates should be loosened and bent. When the plates are bent, they 

can break off. This is not a fault. They can be screwed back on when 

you have finished using the supporting function.

NAVN:

STI:

DIMENSION:

MATERIALE:

DATO:

SIGN:

Krog Iversen & Co A/S

DK-5492 Vissenbjerg©

TG.NR:

EMNE:

C:\Working Folder\Designs\DSA 12\90085003.idw

 

90085003

Målskitse for justerbare ben

09-06-11

BC

Scan DSA 12

VÆGT:

AREAL:

N/A

N/A

13

88

,6

1322

1255,4

1188,8

1122,2

1055,6

989

1388,6

0

449,6

70

136,6

203,2

269,8

336,4

403

Side pieces

Side pieces

When the supporting legs are in their highest position, the stove 

will be 1388.6 mm tall. When they are at the bottom, the stove will 

be 989 mm tall.

Base of Scan DSA 12

NAVN:

STI:

DIMENSION:

MATERIALE:

DATO:

SIGN:

Krog Iversen & Co A/S
DK-5492 Vissenbjerg©

TG.NR:

EMNE:

C:\Working Folder\Designs\DSA 12\90085019.idw

 

90085019

Afmontage sideplade

09-06-2011

BC

Scan DSA 12

VÆGT:

AREAL:

N/A

N/A

NAVN:

STI:

DIMENSION:

MATERIALE:

DATO:

SIGN:

Krog Iversen & Co A/S
DK-5492 Vissenbjerg©

TG.NR:

EMNE:

C:\Working Folder\Designs\DSA 12\90085019.idw

 

90085019

Afmontage sideplade

09-06-11

BC

Scan DSA 12

VÆGT:

AREAL:

N/A

N/A

NAVN:

STI:

DIMENSION:

MATERIALE:

DATO:

SIGN:

Krog Iversen & Co A/S
DK-5492 Vissenbjerg©

TG.NR:

EMNE:

C:\Working Folder\Designs\DSA 12\90085020.idw

 

90085020

Buk af sideplade

09-06-2011

BC

Scan DSA 12

VÆGT:

AREAL:

N/A

N/A

Loosen the screws

Bend the side plates

F

F

Содержание DSA 12

Страница 1: ...of wood burning stoves and we are sure that you will have years of plea sure with your purchase To make the best possible use of your built in stove it is important that you follow our advice and inst...

Страница 2: ...ith flammable materials Positioning near non flammable materials Trims and doors Existing chimney and pre fabricated element chimney Connection between stove and steel chimney Requirements for chimney...

Страница 3: ...parts that are necessary for the operation and safety of the stove are dismantled or removed Technical data and dimensions Materials steel plate cast iron galvanised sheet skamol Surface treatment Se...

Страница 4: ...Working Folder Designs DSA 12 90085002 idw 90085002 M lskitse Scan DSA 12 09 06 11 BC Scan DSA 12 V GT AREAL N A N A 460 840 274 900 989 793 220 323 676 616 939 889 230 Dimension sketch for Scan DSA 1...

Страница 5: ...shared flue Country EN 13229 EC no 90085600 Wood Intermittent EUR Norway Austria Classification Intermittent Klasse 2 Certificate Standard EN 13229 SINTEF 110 0327 15 a B VG Approved by RWE Power AG S...

Страница 6: ...you remove both doors and trims before unscrewing the stove from the pallet This makes it easier to install the stove To remove the doors Loosen the pointed screw remove the screw and spring and lift...

Страница 7: ...flammable mate rials See pages 9 and 10 Positioning near non flammable materials When constructing a brickwork non flammable surround the distance to the stove must be at least 10mm Trims and doors Tr...

Страница 8: ...he stove side plates should be loosened and bent When the plates are bent they can break off This is not a fault They can be screwed back on when you have finished using the supporting function Side p...

Страница 9: ...aterials the height above the floor must be at least 400 mm Installation in connection with flammable materials D Supporting of stove on non flammable side pieces Flammable material Flammable material...

Страница 10: ...IGN TG NR EMNE 90085015 Indbygning i forbindelse med br ndbart loft 01 02 10 BC Scan DSA 12 V GT N A B B Minimum 200 mm Flammable material 200 mm mineral wool Non flammable plate or covering E E 10 Fl...

Страница 11: ...to close it when you are not using the wood stove National and local building regulations must be followed with regard to the connection of fresh air intake Closed combustion system You should use the...

Страница 12: ...N A NAVN STI DIMENSION MATERIALE DATO SIGN Krog Iversen Co A S DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs DSA 12 90085006 idw 90085006 Tilbeh r Konvektionsstudse 09 06 11 BC Scan DSA 12...

Страница 13: ...The stove is equipped with the clean burning technique In order to ensure an optimal combustion of released gases under the incinera tion process air will pass through a specially developed canal syst...

Страница 14: ...ly friendly start to your fire and helps to keep the glass area as clean as possible Continuous firing It is important to reach as high a temperature as possible in the combustion chamber This makes t...

Страница 15: ...are generally better for heating as they burn more evenly and create less ash Other wood types like maple birch and spruce are excellent alternatives Handling Firewood is best if you fell the tree an...

Страница 16: ...heating cooling process These cracks have no influence on the heating performance or lifetime of your stove However if the lining starts to crumble you must replace it The com bustion chamber lining i...

Страница 17: ...SA 12 90085023 idw 90085023 R gvenderplader snittegning 03 02 10 BC Scan DSA 12 V GT AREAL N A N A A A B B A A B B NAVN TG NR EMNE 90085023 R gvenderplader snittegning Scan DSA 12 Upper baffle plates...

Страница 18: ...ing errors or defects You must quote your stove s product registration number when you contact us or your authorised Scan dealer with a warranty claim The warranty covers all parts which in the opinio...

Страница 19: ......

Страница 20: ...Scan A S DK 5492 Vissenbjerg Version GB 90085500 6 29 02 2016...

Отзывы: