background image

Clean combustion

The SCAN 46 uses the "CB technique" (Clean-Burn) to 
ensure an optimally clean combustion. The extra combu-
stion air is preheated and led into the combustion chamber 
close to the ceramic smoke deflector.

Ceramic smoke deflectors

Lift up the lower ceramic smoke deflector, pull out 
the pins in the lateral combustion chamber plates, 
and remove the deflector. The upper deflector is 
removed in the same way.

You have chosen a product from one of Europe's leading 
manufacturers of wood-burning stoves. We are convinced 
that your stove will be to your full satisfaction and give you 
many hours of pleasure if you follow the advice and instruc-
tions of this manual. 

Please read this manual as well as the 

General Instructions 

for Installation

 before beginning the installation.

Congratulations on your new SCAN stove!

2

4

1

3

1   

Ashtray.

 When you open the door, you have access to 

the ashtray, which is placed below the combustion cham-
ber.

Attention! Be careful when you empty ashes from the 

stove. There may be embers left for up to 24 hours after 
the stove was last used.

2   

Handle for shaking grate.

 The stove is equipped with a 

shaking grate. When you activate the grate handle, the 
ashes from the combustion chamber are emptied into the 
ashtray.

3  

Regulation for primary air.

 Push the button sideways. 

Left position is closed and right position is open. The 
primary air is used when lighting and refuelling the stove. 
It should always be closed during continuous firing.

4  

Regulation for combustion air.

 Push the button side-

ways. Left position is closed and right position is open. 
The air is used for combustion and regulates the output 
of the stove.

SCAN 46

The ashtray, shaking grate, and primary air should always 
be closed during continuous firing.

Wood / briquettes

Fuel kg/h (beechwood 

max. 20% humidity)

SCAN 46

1,6 kg

Combustion air %

100

Primary air %

25

Adjustment of the air

Содержание 46

Страница 1: ... ringsv ejledn ing Udga ve 03 03 DK M O N T E R I N G S V E J L E D N I N G med brugs og fyringsanvisning Indhold Generelle råd og anvisninger 2 3 Reklamationsret Type og miljøgodkendelse Udpakning Tilbehør til din pejs Montering af kakler og fedtsten Kvalitetskontrol Anmeldelsespligt Skorstenstjek Skorstensløsninger Bærende underlag Brændbar eller ikke brændbar væg Gulvplade Varmefordeling Selvlu...

Страница 2: ...htray When you open the door you have access to the ashtray which is placed below the combustion cham ber Attention Be careful when you empty ashes from the stove There may be embers left for up to 24 hours after the stove was last used 2 Handle for shaking grate The stove is equipped with a shaking grate When you activate the grate handle the ashes from the combustion chamber are emptied into the...

Страница 3: ...volving base Mounting with elbow See separate instructions delivered with the stove Mounting with direct connection to steel chimney Should only be done in accordance with the instructions from an authorised SCAN dealer See separate instructions delive red with the stove The warranty is invalid if the above is not followed Please do not forget to remove the foil before the first firing Data for ca...

Страница 4: ...ails Technical info Rated output 5 kW Min max 2 7 kW Weight 94 kg Connection piece diameter int 135mm ext 148mm To the middle of the rear outlet only SCAN 46 with firm base Distances to flammable materials mm Production number Write the production number of your stove here so that you have it at hand in case you need to contact us Wall Corner SCAN 46 40o 500 200 800 8 0 0 5 0 0 800 230 230 40o 4 0...