Clean combustion
The SCAN 46 uses the "CB technique" (Clean-Burn) to
ensure an optimally clean combustion. The extra combu-
stion air is preheated and led into the combustion chamber
close to the ceramic smoke deflector.
Ceramic smoke deflectors
Lift up the lower ceramic smoke deflector, pull out
the pins in the lateral combustion chamber plates,
and remove the deflector. The upper deflector is
removed in the same way.
You have chosen a product from one of Europe's leading
manufacturers of wood-burning stoves. We are convinced
that your stove will be to your full satisfaction and give you
many hours of pleasure if you follow the advice and instruc-
tions of this manual.
Please read this manual as well as the
General Instructions
for Installation
before beginning the installation.
Congratulations on your new SCAN stove!
2
4
1
3
1
Ashtray.
When you open the door, you have access to
the ashtray, which is placed below the combustion cham-
ber.
Attention! Be careful when you empty ashes from the
stove. There may be embers left for up to 24 hours after
the stove was last used.
2
Handle for shaking grate.
The stove is equipped with a
shaking grate. When you activate the grate handle, the
ashes from the combustion chamber are emptied into the
ashtray.
3
Regulation for primary air.
Push the button sideways.
Left position is closed and right position is open. The
primary air is used when lighting and refuelling the stove.
It should always be closed during continuous firing.
4
Regulation for combustion air.
Push the button side-
ways. Left position is closed and right position is open.
The air is used for combustion and regulates the output
of the stove.
SCAN 46
The ashtray, shaking grate, and primary air should always
be closed during continuous firing.
Wood / briquettes
Fuel kg/h (beechwood
max. 20% humidity)
SCAN 46
1,6 kg
Combustion air %
100
Primary air %
25
Adjustment of the air