24
Setup Interface and Print results
To use a printer, the operator must select one of printer types before connecting a printer. The
parallel printer port is optional item and it is used for special purpose. Regarding the available
printers, please consult with your dealer.
If the printer type is set to “Serial”, SB1000 /SB-1100 operates with the parameters like below:
Speed (Baud Rate)
: 9600 bps
Parity
: None
Data Bit
: 8
Stop Bit
: 1
The parameters of a printer should be set to as same value as the above description.
The Column Length parameter is to be set to the column length of the printer.
To print the result, press and hold START key for more than 1 second after the machine finished
counting. To print the Grand Total, press and hold START key for more than 1 second while
Display shows the Grand Total.
The other parameters are related with the interface between SB1000 /SB-1100 and other
peripherals like PC.