16
Diagram 1
Installing the Remote Temperature Probe
for SAWO Controls
Diagram 2
DRAWING NOT
TO SCALE
SAWO Steam Generator
(shown with cover removed and NOT installed)
Temperature
Sensing Probe
Knock-out
Temperature
Probe Cable
(9 meters)
Temperature Probe
Connection
Printed
Circuit
Board
Component
shown for
illustrative
purpose
The Remote Temperature Probe is for use with SAWO Control only. Do not
use any other controls. Do not use any other temperature probe with the SAWO control.
Noncompatible products may result in an inoperative control and a hazardous condition.
Install the SAWO Control according to the installation and operation
instructions supplied with the control. Failure to do so may result in an inoperative
control and a hazardous condition.
1. Determine the location of the Remote Temperature Probe.
The Remote Temperature Probe must be installed:
a. On a vertical surface
b. 1.2-1.5 meters above the floor
c. Away from the steam head
d. Not exposed to direct steam emission.
The probe has an integral 9 meter
cable. Insure that the probe and/or
steam generator are located accordingly.
Contact a SAWO technical service
representative if a longer cable is
required.
2. Drill an 8mm hole in the wall as
shown in Diagram 1. Do not
oversize or undersize the hole.
Clean area thoroughly.
3. Remove the knock-out from the
steam generator jacket as shown in
Diagram 2.
4. Insert the remote temperature
probe cable through the knock-
out and connect to the
connector on the steam
generator printed
circuit board marked "TEMP
PROBE" as shown
in Diagram 2.
NOTE:
For illustrative purposes only.
Consult. with qualified designer,
architect or contractor for steam
room construction details.
!
CAUTION
!
CAUTION
STR
230V 1N~
kW
KATSO OHJE
ISTA
TÄRKEÄT LIS
ÄOHJEET
BEACHTEN
SIE DIE
ZUSÄTZLICHE
N
WICHTIGEN
ANWEISUNG
EN IN DER
BEDIENUNG
SANLEITUNG
READ THE
MANUAL FO
R
ADDITIONA
L IMPORTAN
T
INSTRUCT
IONS
LÄGG MÄR
KE TILL DE
VIKTIGA
TILLÄGGS
ANVISNINGA
RNA
17
5. Route the end of the temperature probe cable with the
temperature probe through the wall into the steam room
as shown in Diagram 3.
IMPORTANT NOTE:
Do not strain, staple, pinch or otherwise
damage the probe cable.
6. With a minimal length of the cable exposed apply silicone
(provided) to the hole in the wall as required to create a
moisture seal as shown in Diagram 3.
7.
Insure a minimum of 6mm of the temperature
bulb is exposed to the air. Failure to do so may result in an
inoperative control and a hazardous condition.
The exposed area of the temperature bulb
mustbe free of silicone or any materials that prevent direct
exposure to the steam room air. Failure to do so may
interfere with the ability to sense temperature and may
result in excessive steam room temperatures.
INSTALLED REMOTE
TEMPERATURE PROBE
6mm
Minimum
13mm
Maximum
Silicone Sealant
Cable
Wall
SECTIONAL VIEW
Steam Room Interior
Diagram 3
Diagram 4
Installing the Remote Temperature Probe
(cont.)
!
WARNING
!
WARNING
Push the temperature cable and bulb into hole as required
to leave minimum 6mm, maximum 13mm of the bulb
exposed as shown below.