background image

Optional Tandem Cable

-

for connecting 2-5 steam generators in tandem

1. Turn on control. Follow specific instruction sheet provided with controls.
2. Steam will begin to appear in 5 minutes at the steam head. Steam will shut off when desired

temperature is reached and will automatically resume when room temperature drops below
set point.

3. Steam will shut off automaticaly when control counts down to zero. to shut steam off manually,

turn control OFF. To clear steam from enclosure area, turn shower on before opening door.

4. If unit does not start and control does not turn ON (control display does not light up) then turn

breaker off for twenty seconds and try again.

Refer to specific instruction sheets for installation, operation and maintenance of optional
equipment and accessories.

SAWO steambath generators require little maintenance. Other than periodic draining,
maintenance procedures are minimal. Every 2 months, or more often in "hard" water areas, the
manual drain valve should be opened fully flushing out accumulated materials, salts and other
particles which are naturally by-products of boiling water.

NOTE:

Flush a minimum of two hours after the control has been turned off to insure that the

water has cooled.

Draining immediately after a steam cycle may expose PVC and other piping

to high temperature water. Check local requirements. The unit will refill automatically when
the control is activated again. In areas of very hard water, a SAWO automatic drain
system is recommended for generator longevity.

Optional Equipment

Initial Start-Up and Checkout

Maintenance

OPTIONAL TANDEM CABLE
FOR 2-5 GENERATORS

Length is 9 meters

3, 4 OR 5 SAWO UNITS

S

WATER FEED

SOLENOID

VALVE

LIGHT
BLUE

ONTACT

OR

CONTROL BOARD

GRAY

WHITE

TRANSFORMER

POWER INPUT

L

N

GREEN

FUSES

ROUND

WHITE

BLACK

BLACK

WHITE

DARK
BLUE

TO
PROBE

SAWO

Control

Automatic Drain

PLUG THIS END

TO MASTER UNIT

FACTORY
WIRING

FIELD
WIRING

PURPLE

TO THIRD UNIT

TO FOURTH UNIT

TO FIFTH UNIT

S

HEATING
ELEMENT

CO

WATER FEED

SOLENOID

VALVE

CONTROL BOARD

WHITE

GRAY

TRANSFORMER

POWER INPUT

L

N

PURPLE

GREEN

FUSES

GROUND

LIGHT
BLUE

WHITE

BLACK

BLACK

WHITE

DARK
BLUE

TO
PROBE

Automatic Drain

SECOND UNIT

MASTER UNIT

HEATING

ELEMENT

CONTACTOR

GROUND

HEATING

ELEMENT

CONTACTOR

10

!

WARNING

11

Automatic drain Cord

Automatic drain Valve

Automatic drain Cord Connector

End
"A"

End
"B"

Plumb to Drain

Line in accordance

with Code

Arrow indicates

correct direction

of flow

Drain Valve

Nipple

Plumb to

Drain Line

Automatic
drain
Valve

Plumbing to be performed by a qualified licensed
plumber and shall be in accordance with applicable
national and Local Codes. Unit drains by gravity.
A drain line that is lower than Automatic drain
assembly must be available. The Automatic drain
valve outlet is threaded 15mm. Check plumbing
code for receptor, trap and vent requirements.

Use copper or brass nipple 15mm x

90mm

or longer (not supplied) to connect the Automatic
drain valve (end "B") to the Drain Valve (valve end
"A" & "B" are indicated on bottom of Automatic
drain Valve).

DO NOT REMOVE THE DRAIN VALVE.

Removal may cause equipment and property
damage. If there is not enough room for the valve,
an elbow and a short nipple (not provided) can
be added.

Installation Instructions

1. Disconnect all power supplied to the unit.

2.

3.

4. Open Drain Valve (handle must be aligned with

brass nipple as shown).

5. Connect the Automatic drain cord connector to the

two pin connector as shown.

Do not drain into a steam enclosure or

any location where accidental contact with drain
water may occur. In the event of a power failure, the
Automatic drain valve will open and discharge hot water.

Operation

The optional Automatic drain
feature automatically drains
the SAWO system following
each use. the stainless steel
tank is flushed and remains
empty until the steam
generator is used again.
A time delay (about 2
hours) allows the water to
cool down before it drains
resulting in a safe gentle
operation.

Drain Valve

(shown in the correct open position)

DO NOT REMOVE THIS DRAIN VALVE

Steam Generator

Nipple

(copper or
brass nipple
15mm x

90mm

or longer
(not supplied))

Box Contents:

* Automatic drain Valve with Cord
* Installation instructions

DO NOT TURN OR REMOVE THE DRAIN VALVE

Steam Generator

Automatic drain shown fully assembled

NOTE:

For illustrative purposes only.

!

WARNING

!

CAUTION

(2) Pin Connector

for Automatic

drain

STR

230V 1N~

kW

KATSO OHJE

ISTA

TÄRKEÄT LIS

ÄOHJEET

BEACHTEN

SIE DIE

ZUSÄTZLICHE

N

WICHTIGEN

ANWEISUNG

EN IN DER

BEDIENUNG

SANLEITUNG

READ THE

MANUAL FO

R

ADDITIONA

L IMPORTANT

INSTRUCT

IONS

LÄGG

MÄRKE TILL

DE

VIKTIGA

TILLÄGGSA

NVISNINGAR

NA

STR

230V 1N~

kW

KATSO OHJE

ISTA

TÄRKEÄT LIS

ÄOHJEET

BEACHTEN

SIE DIE

ZUSÄTZLICHE

N

WICHT

IGEN

ANWEISUNG

EN IN DER

BEDIENUNG

SANLEITUNG

READ THE

MANUAL FO

R

ADDITIONA

L IMPORTANT

INSTRUCT

IONS

LÄGG MÄR

KE TILL DE

VIKTIGA

TILLÄGGS

ANVISNINGA

RNA

Содержание STR120-3

Страница 1: ...of non skid floor materials or the use of proper footwear is recommended at all times IMPORTANT Read the manual provided for use and safety information SAWO SAWO Inc SAWO Building Mactan Export Processing Zone 2 Cebu Philippines 6015 www sawo com W A R N I N G MANUAL RESIDENTIAL STEAMBATH GENERATOR SYSTEMS Congratulations on your purchase of SAWO Steam Generator Please read the manual carefully be...

Страница 2: ...units are intended to be operated with SAWO Controls only and are to be installed strictly in accordance with the specific instructions contained in this manual and as supplied in the manuals provided with the controls Electrical shock hazard SAWO steam generators are connected to 220 240V One Phase models only STR45 1 STR60 1 STR75 1 and STR90 1 or 380 430V Three Phase models only STR45 3 STR60 3...

Страница 3: ... permitted by codes Do not use black galvanized or PVC pipe Water Supply 10mm Connect hot or cold water line Hot water line is preferable however hot water should not exceed 70ºC Provide a shut off valve in the water supply line upstream of the steambath generator Do not overheat inlet solenoid valve with solder connections Overheating will damage parts Flush inlet water line thoroughly before mak...

Страница 4: ... 5 All electrical wiring to be installed by a qualified licensed electrician in accordance with local electrical code Power Wiring See page 8 Field Power Wiring diagrams Check power voltage Use 220 240V to connect a single phase SAWO residential steambath generator Use 380 430V to connect a 3 phase SAWO residential steambath generator Use minimum 90ºC 600V rated insulated copper conductors only si...

Страница 5: ...G R E E N T R A N S F O R ME R G T O P R O B E SAWO CONTROL AUTOMATIC DRAIN 8 Field Power Wiring Contactor Knock out N L Ground Ground Lug Models STR45 1 STR 60 1 STR75 1 and STR90 1 Models STR45 3 STR60 3 STR75 3 STR90 3 STR120 3 and STR 150 3 _________________________________________________ _________________________________________________ TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY D...

Страница 6: ...Cord Connector End A End B Plumb to Drain Line in accordance with Code Arrow indicates correct direction of flow Drain Valve Nipple Plumb to Drain Line Automatic drain Valve Plumbing to be performed by a qualified licensed plumber and shall be in accordance with applicable national and Local Codes Unit drains by gravity A drain line that is lower than Automatic drain assembly must be available The...

Страница 7: ...om volume in m a L x W x H 2 Add 15 of a for each of the following design features that describe the steambath enclosure b Each exterior wall or uninsulated attic or crawlspace above or below ceiling or floor c Tile on mud wall d An extra glass panel in addition to the door e A cast iron tub or marble bench f Each foot exceeding 2 5 meters height 3 If the interior wall construction material within...

Страница 8: ...optional Safety Valve Steam Outlet Water Feed Hose Plug and Play Connection Water Feed Water Feed Solenoid Transformer Liquid Level Circuit Board STR120 3 and STR150 3 with Automatic drain shown with cover removed Access Cover Knock out Liquid Level Probe Power Block Power Supply Drain Line Transformer Liquid Level Control Board Water Feed Solenoid Water Feed Hose Water Feed Steam Outlet Safety Va...

Страница 9: ... knock out and connect to the connector on the steam generator printed circuit board marked TEMP PROBE as shown in Diagram 2 NOTE For illustrative purposes only Consult with qualified designer architect or contractor for steam room construction details CAUTION CAUTION STR 230V 1N kW KATSO OHJEIST A TÄRKEÄ T LISÄOHJ EET BEACHTE N SIE DIE ZUSÄTZL ICHEN WICHTIG EN ANWEISU NGEN IN DER BEDIENU NGSANL E...

Страница 10: ...to the steam generator Connect the connector to the steam generator CAUTION Installation Instructions SAWO Controls Installation Operation Maintenance Manual IMPORTANT Turn power to the steam generator OFF before installing the control Failure to turn the power off will result in an inoperable control IMPORTANT Do not strain staple pinch or otherwise damage the control cable Route cable as require...

Страница 11: ... the current temperature setting The new and desired temperature setting Set Point value will remain for 5 seconds on the LED display as a confirmation of the new value you have selected The Set Point indicator shows the desired temperature NOT the actual temperature Temperature can be adjusted in 0 5 degree increments from 40 to 49ºC When ambient temperature is 0 5ºC lower than the Set Point the ...

Страница 12: ...manufactured by manufactured by www sawo com info sawo com Subject to change without notice ...

Отзывы: