1. Setup and use of the Combi Heater
1.1.
1.2.
Assembly of parts
1.1.1. Ball valve
Before installing the ball valve wrap Teflon tape around the nipple’s thread to ensure water proof
insulation. When attaching and detaching the ball valve make sure that the valve’s handle is in
closed position (see Fig. 1).
1.1.2. Scent basins
Scent basins are to be attached as per Figure 2. Handle scent basins with care as they might break
when dropped on the floor or any hard surface.
1.1.3. Steamer cover
To detach or attach the steamer cover, follow the instruction given in Figure 3.
1.1.4 Water inlet for automatic refill
Water inlet is described in Fig 1. Pressure of the water supply should be 1-3 bar.
Loading the Combi Heater with stones
The main purpose of the stones in the Combi Heater is to store enough energy to efficiently
vaporize the water thrown on top of the stones to maintain correct humidity in the sauna room.
The stones must be removed at least once a year or every 500 hours which ever occurs first. All
stone crumbles must be removed from the heater then load new stones as described hereinafter.
To verify the required amount of stones, see technical data in Figure 10.
Kuva 3
Fig. 3
Attach the steamer cover as shown
Vesisäillion kannen asennus
Remove the steamer cover as shown
Vesisäiliön kannen irroitus