![Sawo ARIES ROUND ARI3-45Ni Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/sawo/aries-round-ari3-45ni/aries-round-ari3-45ni_manual_1204452026.webp)
troublEsHooting
If an error occurs, the heater will be switched off.
There will be a warning beep and the code for
the error will be displayed in the control panel.
See more details on the table below
warning!
Please note, only a qualified
electrician or maintenance per-
sonnel is allowed to make the
service operations and repairs!
Code
Problem
Solution
E1
Temperature sensor 1 is not
connected.
Check the wire between the sensor and the control
unit. If there is no problem with the wires and they
are correctly installed, check the sensor.
If no reason for the problem can be found, contact
the retailer.
E2
Temperature sensor 1 is short
circuit.
E3
Temperature sensor 1 is short
circuit.
Check the wire between the sensor and the control
unit. It has probably overheated. The reason for
it needs to be discovered before using the sauna
again. A new sensor is needed.
If no reason for the problem can be found, contact
the retailer.
E4
Temperature sensor 2 is not
connected.
Check the wire between the bench sensor and the
control unit. If there is no problem with the wires
and they are correctly installed, check the sensor.
The heater can still be used with the sensor 1 only,
but 2 sensors are needed for the steamer.
If a new sensor is needed or no reason for the prob-
lem can be found, contact the retailer.
E5
Temperature sensor 2 is not
connected.
E6
Combined Temperature
/ Humidity sensor is defective.
E7
Communication failure.
Check the RJ12 cable. If the area where the cable
is located has many other cables, it can cause inter-
ference problems. If built-in model is used, remove
the control panel. Wipe the pin header contact to
remove any dirt. Assemble back the control panel in
correct position and make sure the six pin header
connectors are properly inserted to the socket.
If no reason for the problem can be found, contact
the retailer.
E8
Temperature is greater than the
maximum temperature.
Ota yhteyttä valtuutettuun sähköasentajaan. Älä
käytä kiuasuta ennen kuin syy on selvinnyt ja kor-
jattu.
ENGLISH
27