MaxiMuM sEssion tiME
The maximum sauna session time depends on the purpose of the sauna. For domestic use,
the total on-time of the sauna is limited to 6 hours. It includes pre-run time and the session
time*. The factory setting for the control unit is 6 hours.
For condominiums, hotels and similar locations, the operating period of the sauna heater is
limited to 12 hours, including the pre-run time and the session time.
For public sauna, the operating period of the sauna heater can be either 18 or 24 hours.
Please note, if the public sauna is set to 24 hours, it will be on constantly. It needs to be
continuously attended.
The maximum heater on-time is set by the jumpers on SCB1 in the power controller (See
page 16). Jumpers 3, 4 and 5 are meant only for public sauna rooms. Only a qualified
electrical can change the settings. The standards and regulations of the country where the
control unit is installed must be followed, when setting the jumpers. When no jumpers are
placed, the default time is 6 hours. See the Table.
tHE HEatEr Main switcH
The heater main switch can be found on the lower part of
the heater. Using this switch, you can isolate the electronics
from the mains power supply.
In order to put the unit into operation, switch to the first
position (switch position I). In this switch position all con-
trol unit’s functions work normally.
In case of breakdown, press the control unit switch on the
left part of the rocker to the middle position (switch position
0). The unit is now completely switched off.
In order to switch on the light in the sauna when the unit
is switched off, press on the left part of the rocker to the
second position (switch position II). Quality requirements
for water which is thrown to the heater