4
Installation
At the top of the waterfall, prepare the
area for installation by excavating a 9” x
34” x 6” deep hole. Compact the soil in the
bottom of the hole to prevent unwanted
settling.
The Livingponds Filter 070 includes two
3” inlets (on either side of the housing).
Select the unused side and apply glue to
the ABS plug (provided).
Before glue dries, firmly press plug into
unused Livingponds Filter inlet.
For 1 1/2” or 2” kink free hose, wrap the
inlet barb's threads with included teflon
tape and screw into reducer bushing pro-
vided. Rigid or flexible PVC can be glued
directly to filter inlet or reducer bushing.
Install inlet assembly by first applying a
layer of PVC glue to the outside of the
reducer bushing.
Before glue dries, firmly press inlet assem-
bly into Livingponds® Filter inlet.