MINI MEL/MINI BLANCO/
MELODY/BLANCO/BLANCO PRO/SOL
Underwater LED Lights
READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
CAUTION! SAFETY PRECAUTIONS
TURN OFF MAIN POWER TO LIGHT BEFORE INSTALLATION
/SERVICE
SAVI Lights are a low voltage light and should NEVER be electrically
connected to a power source other than an approved pool “Safety Rated”
UL Listed outdooor rated Class 3,
12VAC Transformer. Failure to comply
will either damage or destroy SAVI
Lights and VOID the Warranty.
STEP 1
The light
must be installed in or on a wall of the pool (or
water feature) with the top of the lens opening not less than 4
inches (10.16cm) below the normal water level of the pool.
STEP 2
Snake the 2-conductor electric cord through the conduit outlet
of the wall
into the conduit and up to the location of
the
12VAC pool transformer. Cut off excess cord after allowing
for
service and length of run to the transformer. Pull the
snug
to the wall
STEP 3
Using
enclosed
Lens Key, thread the
light
into the wall
fitting
until
it
is
snug.
P
lease provide Pool Owner with minimum of 1 key upon job
completetion (see winterization clause above)
NOTE: Requires the use of a 1-1/2” threaded wal
l fitting.
Product Names
WATTS
AMPS
MINIMUM CONDUIT
REQUIREMENTS
14
1.2
9”
10
0.83
20
1.67
28
2.3
MINI MEL
MINI BLANCO
SAVI-MELODY
MELODY BLANCO
BLANCO PRO
SAVI
SOL
14"
NOTE: Make sure all protective coverings have been removed.
An example of an approved pool transformer is the Intermatic model PX-100 or PX-300.
Refer to WIRE GAUGE AND WIRE LENGTH guide for for proper wire gauge size in
reference to the use of Junction Boxes installations. NOTE: SAVI Lights can be used
with any UL Listed outdoor rated Class 3, 12VAC transformer provided the wattage and
amperage is not exceeded by the total wattage and amperage in use.
A Division of Next Step Products
9400 SOUTHRIDGE PARK COURT SUITE 200
ORLANDO, FLORIDA 32819 USA
Tel: 407.855.5630
Fax: 407.210.8679
nextstepproduct.com
4” MIN. FROM WATER
LEVEL TO TOP OF LENS
1.5” Pipe
1” min. Pipe
Sweeps ONLY
No 90 degree bends
4” MIN. FROM WATER
LEVEL TO TOP OF LENS
12VAC Pool Transformer
Allow 18” - 24”
slack for
Service Loop
Conduit to 12VAC transformer
Tighten
NOTE: Service
Loop not applicable
for Junction Box
Installations.
1.5” THREADED WALL FITTING
1.5” Pipe through bond beam for a minimum of 14” then 1” conduit
min. with sweeps / no 90 degree bends. We highly recommend
the use of 1
.5
" pipe throughout the entire width of the bond beam.
NOTE
: Use of 1.5” pipe with 14” min. length will accommodate all
SAVI Lighting nicheless products.
See Minimum Conduit
Lengths listed above.
Winterization Clause
Pool Water Level must be drained down 12” below light(s) position in pool wall.
We
recommend that the lights be loose
ne
d from their wall
fitting
to allow drainage of water
that might have accumulated within conduit. Consult your local Swimming Pool
Professional for proper local area winterization processes.
At NO TIME should water be
removed from the pool without checking ground water tables.
Small Gasket
Large Gasket
Flat Gasket
NOTE:
For Vinyl wall Fittings use both rubber
gaskets.
For Gunite and Fiberglass remove
the Small gasket and use the Large one only.
4” MIN. FROM WATER
LEVEL TO TOP OF LENS
Vertical Installation for
Benches, Swimouts and
Fountains
NOTE
: No separate ground or bonding wire is required for
the Melody, Blanco, Blanco Pro or SOL low voltage lights which
have no exposed metal. They do not require a niche.
For Replacement LED Light Cartridges
see Light Cartridge Replac
e
ment Page
9"
14"
All products listed above come in a variety of cord length
Typical Leng
t
hs are: 30-50-100 & 150FT
18"-24" of excess cord recommended as service loop.
LIGHTS ARE SERVICABLE - DO NOT
REMOVE ENCLOSURE/CORD FROM CONDUIT
NOTE:
Check with Local Building officials as to what conduit/pipe is acceptable
INSTALLATION INSTRUCTIONS
-
2013/14 SERVICABLE PRODUCT
6
5
.5
.42
3
”
3
”