IMPORTANT: READ FIRST
SAVI LED UNDERWATER LIGHTS ARE LOW VOLTAGE FIXTURES. IMPROPER
WIRE GAUGE AND WIRE LENGTH CAN AFFECT THE PERFOMANCE OF THESE
PRODUCTS. FOLLOW THE GUIDES BELOW TO DETERMINE THE PROPER
OPERATION AND OPTIMUM PERFORMANCE OF SAVI LIGHTS.
!
WIRE GAUGE & WIRE LENGTH GUIDE
JUNCTION BOX
Black Hot Line
Cri
m
p Style Connectors
Recommended
Cri
m
p Style Connectors
Recommended
BLK
BLK
WHT
WHT
White Neutral
Green Ground
LOW VOLTAGE
(12VAC)
TRANSFORMER
PX100 or PX300
NOTE:
This Diagram is to be used as a guide line only for a typical System Installation and should only be used
as such. It is the Installers sole responsibility to verify and assure that proper gauging of secondary wiring
from the Transformer to the J-Box are in compliance with your local, State and National Electrical Codes.
JB
T
JUNCTION BOX
BUS BAR
PX100 / PX300
MAX WATTAGE
MAX WATTAGE
MAX WATTAGE
0-50ft
100ft cord
168W
12GA
12V
SAVI Pool and Spa | 9400 Southridge Park Court Suite 200 | Orlando | Florida | 32819 | USA | T. 407.855.5630 nextstepproduct.com
JB
T
100ft
50ft cord
126W
10GA
12V
JB
T
1
3
0ft
2
0ft cord
98W
8GA
12V
JB
T
JUNCTION BOX
BUS BAR
PX100 / PX300
0 - 50ft
100ft cord
210W
12GA
13V
JB
T
51 - 100ft
50ft cord
168W
10GA
13V
JB
T
101 - 125ft
10ft cord
154W
8GA
13V
JB
T
JUNCTION BOX
BUS BAR
PX300 ONLY
0-50ft
100ft cord
240W
12GA
14V
JB
T
51 - 100ft
50ft cord
224W
10GA
14V
JB
T
101 - 125ft
10ft cord
196W
8GA
14V
NOTE: The use of Solid Core over Stranded wire and terminating at Bus Bars is strongly recommended.
A Division of Next Step Products
9400
SOUTHRIDGE
PARK
COURT
SUITE
200
ORLANDO,
FLORIDA
32819
USA
Tel:
407.855.5630
Fax:
407.210.8679
nextstepproduct.com
NOTE
: Min. 1
2
VAC: / Max 13VAC. The maximum run of service between transformer and lights should not
exceed 150ft in total length, inclusive of the use of J Box or not.