12
SL-1000 Owner’s Manual
Part No. 000729, 12-m11-2012
Diagnostics
For codes displayed on the diagnostic display, refer to the following table to
help diagnose and correct any faults.
NOTE
If the recommended corrective action provided in the table does
not solve the problem, contact your authorized dealer for
assistance.
Diagnostic Codes
Code
Status/Fault
Recommended Corrective Action
No display.
Press the UP/DOWN rocker switch and
see if the display comes on. Check that
the key switch and ON/OFF switch are
turned on.
_
On when the stairlift is okay; ready
to use.
Flashing when the stairlift is
running.
No action required.
0
Final limit switch is activated or
swivel seat switch is activated.
Check that the key switch is ON and the
seat is fully swivelled to the riding
position.
1
Batteries require charging.
Check that the charger is plugged in
and charging.
2
Batteries not charging.
Check that the charger is plugged in
and charging.
3
Upper limit safety switch is
activated.
You have reached the upper limit. Run
the unit in the down direction.
4
Safety edge switch (bumper) in up
direction is activated.
Remove any obstacle that may have
activated the switch.
5
Underpan switch is activated.
Remove any obstacle from underneath
the footrest.